A new configuration for right ventricular assist with skeletal muscle ventricle. Short-term studies.

نویسندگان

  • H Niinami
  • T L Hooper
  • R L Hammond
  • R Ruggiero
  • A Pochettino
  • M Colson
  • L W Stephenson
چکیده

BACKGROUND Previous attempts to provide right heart assistance with skeletal muscle ventricles (SMVs) have been frustrated by the low preload supplied by the systemic venous blood pressure. In the present study, right ventricular pressure was exploited to provide more optimal preload, the SMV being connected by valved conduits between right ventricular free wall and the main pulmonary artery. METHODS AND RESULTS SMVs were constructed from the right latissimus dorsi muscle in seven mongrel dogs. Following a delay period of 4 weeks, SMVs were preconditioned with 2-Hz continuous stimulation for 5-6 weeks. The SMV was then connected to the right ventricle using a porcine valved Dacron conduit. A similar valved conduit connected the SMV to the main pulmonary artery that had been ligated proximally. SMVs were stimulated with 33-Hz burst frequency to contract synchronously with ventricular diastole in a 1:2 mode. The stimulator was intermittently turned off to permit comparison of assisted and nonassisted circulation. Cardiac output increased by 27% at 1 hour (1,437 +/- 54 versus 1,140 +/- 64 ml/min, p less than 0.005) and by 30% at 4 hours (1,403 +/- 161 versus 1,074 +/- 99 ml/min, p less than 0.005), systemic arterial systolic pressure increased at 1 hour by 12% (87.1 +/- 4.9 versus 78.0 +/- 4.9 mm Hg, p less than 0.05) and by 13% at 4 hours (81.4 +/- 2.8 versus 72.3 +/- 3.4 mm Hg, p less than 0.005), and peak pulmonary arterial pressure increased at 1 hour by 35% (28.0 +/- 2.1 versus 20.9 +/- 1.8 mm Hg, p less than 0.01) and by 37% at 4 hours (31.5 +/- 2.6 versus 23.0 +/- 0.4 mm Hg, p less than 0.05). Peak SMV pressure was 52.8 +/- 2.0 mm Hg at 1 hour and 49.9 +/- 3.3 mm Hg at 4 hours (p = NS). CONCLUSIONS The improved preload supplied by this configuration of right ventricular assist enabled an SMV to provide stable and effective circulatory support throughout the 4-hour duration of the experiment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power output of skeletal muscle ventricles in circulation: short-term studies.

Skeletal muscle ventricles (SMVs) were constructed from preconditioned latissimus dorsi muscles in eight dogs and then connected to each animal's systemic arterial circulation in short-term experiments. The lengths of time that SMVs could produce hemodynamic work as left ventricular assist devices were recorded. After 4 hr of continuous pumping at approximately 55 beats/min, six of eight SMVs w...

متن کامل

Tissue Velocity Imaging for Monitoring of Muscle Function in Circulatory Assist Systems

In a series of studies we tested potential applications of tissue velocity imaging (TVI) for pre-surgical and post-surgical assessment in skeletal muscle circulatory assist systems. TVI is an ultrasound modality which is capable of measuring velocities within solid tissues such as skeletal muscle. An initial evaluation in healthy volunteers demonstrated that TVI can characterise the rapid phase...

متن کامل

Implantation of Short-Term and Long-Term Right Ventricular Assist Devices

The last decade has seen considerable growth in the use of left ventricular assist devices (LVAD), in end-phase heart failure treatment. The indications, contraindications and implantation techniques are well-defined. However, information about mechanical support for right ventricular failure is lacking. The aim of this communication is to present alternative techniques for implantation of shor...

متن کامل

In vivo evaluation of the Nimbus axial flow ventricular assist system. Criteria and methods.

Continuing in vivo trials are being conducted at the University of Pittsburgh using the Nimbus axial flow blood pump (AxiPump). To date, 14 sheep experiments have been performed to address several issues related to short-term support. Six acute experiments (< 6 hr) have been performed to assess hemodynamics related to speed regulation and to determine anatomic placement of the pump and cannulae...

متن کامل

Holt-Oram Syndrome: A Rare Variant

Holt-Oram syndrome is an autosomal dominant disorder, characterised by skeletal abnormalities of the upper limb associated with congenital heart defect, mainly atrial and ventricular septal defects. Skeletal defects exclusively affect the upper limbs in the preaxial radial ray distribution and are bilateral and asymmetrical. They range from clinodactyly, absent or digitalised thumb, hypoplastic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 84 6  شماره 

صفحات  -

تاریخ انتشار 1991