Comparative evaluation of the BD Phoenix and VITEK 2 automated instruments for identification of isolates of the Burkholderia cepacia complex.

نویسندگان

  • Sylvain Brisse
  • Stefania Stefani
  • Jan Verhoef
  • Alex Van Belkum
  • Peter Vandamme
  • Wil Goessens
چکیده

We evaluated two new automated identification systems, the BD Phoenix (Becton Dickinson) and the VITEK 2 (bioMérieux), for identification of isolates of the Burkholderia cepacia complex (BCC). The test sample included 42 isolates of the highly virulent and epidemic genomovar III, 45 isolates of B. multivorans, and 47 isolates of other members of the BCC. Rates of correct identification by the BD Phoenix and VITEK 2 were similar when all BCC isolates were considered (50 and 53%, respectively) but differed markedly for genomovar III (71 and 38%; P < 0.01) and for B. multivorans (58 and 89%; P < 0.001). For the BD Phoenix as well as the VITEK 2, taking all 134 isolates of the BCC together, rates of correct identification of clinical isolates (56 and 55%, respectively; n = 85) were higher than those of environmental isolates (21 and 39%, respectively; n = 28). Clinical isolates of genomovar III (n = 27) showed correct identification rates of 81% (BD Phoenix) and 48% (VITEK 2) (P < 0.01). Rates of misidentification for BD Phoenix and VITEK 2 were 9 and 17% for genomovar III, 22 and 7% for B. multivorans, and 36 and 13% for the other BCC members (P < 0.01), respectively. More than half of the isolates misidentified by each instrument were identified as Ralstonia pickettii, Ralstonia paucula (CDC IV C-2 group), Alcaligenes faecalis, Achromobacter spp., or, for the VITEK 2, "various nonfermenters." This study reemphasizes that confirmatory identification of BCC, preferably by molecular methods, is highly recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of the comparative workflow and performance characteristics of the VITEK 2 and Phoenix systems.

The VITEK 2 (bioMérieux, Marcy L'Etoile, France) and the Phoenix systems (BD Diagnostic Systems, Sparks, Md.) are automated instruments for rapid organism identification and susceptibility testing. We evaluated the workflow, the time to result, and the performance of identification and susceptibility testing of both instruments. A total of 307 fresh clinical isolates were tested: 141 Enterobact...

متن کامل

Evaluation of the Etest ESBL and the BD Phoenix, VITEK 1, and VITEK 2 automated instruments for detection of extended-spectrum beta-lactamases in multiresistant Escherichia coli and Klebsiella spp.

Seventy-four isolates of multiresistant Escherichia coli and Klebsiella spp. recovered during a 3-year period and 17 control strains with genotypically identified beta-lactamases were tested for the production of extended-spectrum beta-lactamases (ESBLs) by using the Etest and the VITEK 1, VITEK 2, and Phoenix automated instruments. The use of the Etest was evaluated by investigating its accura...

متن کامل

Reliability of automated biochemical identification of Burkholderia pseudomallei is regionally dependent.

Misidentifications of Burkholderia pseudomallei as Burkholderia cepacia by Vitek 2 have occurred. Multidimensional scaling ordination of biochemical profiles of 217 Malaysian and Australian B. pseudomallei isolates found clustering of misidentified B. pseudomallei isolates from Malaysian Borneo. Specificity of B. pseudomallei identification in Vitek 2 and potentially other automated identificat...

متن کامل

Identification and antimicrobial susceptibility testing of clinical isolates of nonfermenting gram-negative bacteria by the Phoenix Automated Microbiology System.

The Phoenix Automated Microbiology System (Becton Dickinson, Sparks, MD) was evaluated for its ability to identify nonfermenting gram-negative pathogens and measure their drug susceptibility. Isolates producing rare extended-spectrum beta-lactamases (PER-1, IMP-2, VIM-1, and VIM-2) were included in the study. Species identification was compared to that given by the ATB System (bio-Mérieux, Marc...

متن کامل

Detecting imipenem resistance in Acinetobacter baumannii by automated systems (BD Phoenix, Microscan WalkAway, Vitek 2); high error rates with Microscan WalkAway

BACKGROUND Increasing reports of carbapenem resistant Acinetobacter baumannii infections are of serious concern. Reliable susceptibility testing results remains a critical issue for the clinical outcome. Automated systems are increasingly used for species identification and susceptibility testing. This study was organized to evaluate the accuracies of three widely used automated susceptibility ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 40 5  شماره 

صفحات  -

تاریخ انتشار 2002