Abnormalities of cardiac sympathetic function in pacing-induced heart failure as assessed by [123I]metaiodobenzylguanidine scintigraphy.

نویسندگان

  • W W Simmons
  • M R Freeman
  • E A Grima
  • T W Hsia
  • P W Armstrong
چکیده

BACKGROUND Increased activity of the sympathetic nervous system contributes significantly to the pathophysiology of heart failure. However, cardiac efferent sympathetic function has not been well characterized in this disorder. In this study, we evaluated cardiac sympathetic innervation using [123I]metaiodobenzylguanidine (MIBG) and compared this with left ventricular (LV) tissue norepinephrine concentration and myocardial perfusion, assessed by 201Tl, in a canine model of heart failure. METHODS AND RESULTS Planar and tomographic cardiac imaging was performed for MIBG and 201Tl in 23 dogs: 8 normal dogs (group 1) and 15 dogs with heart failure induced by right ventricular pacing at 250 beats per minute either continuously for 3 weeks (group 2) or intermittently for 7 weeks (group 3). Plasma and LV tissue norepinephrine concentrations were also measured. Scintigraphic studies in group 2 demonstrated reduced cardiac MIBG activity at heart failure (0.17 +/- 0.04 versus 0.29 +/- 0.05 counts per megabecquerel per pixel at baseline, mean +/- SD; P = .0001), whereas thallium activity was unchanged from baseline. This reduction in cardiac MIBG activity with heart failure was associated with increased intraimage variability in the distribution of MIBG activity (21 +/- 8% versus 13 +/- 7% at baseline, mean +/- SD; P = .0001). The MIBG heart-to-lung ratio was calculated for all groups to control for the inhibitory effect that plasma norepinephrine has on the neuronal uptake of MIBG. There was a positive correlation between LV tissue norepinephrine and the MIBG heart-to-lung ratio (r = .67; P < .001; n = 22), for which the group 2 heart failure animals had the lowest values. No relation existed between plasma norepinephrine concentration and the MIBG heart-to-lung ratio. In addition, regional LV tissue norepinephrine concentration and MIBG activity were both lowest at the apex in normal (group 1) and heart failure (group 2) dogs. The MIBG heart-to-lung ratio also correlated inversely with cardiac filling pressure (r = -.59; P < .05) and heart rate (r = -.65; P < .01) and positively with cardiac output (r = .53; P < .05). CONCLUSIONS Heart failure is associated with severe cardiac adrenergic dysfunction manifested by reduced MIBG activity and increased heterogeneity in the LV distribution of MIBG. Furthermore, MIBG scintigraphy is a simple noninvasive method for assessing global and regional LV tissue norepinephrine levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Uptake index of 123I-metaiodobenzylguanidine myocardial scintigraphy for diagnosing Lewy body disease

Objective(s): Iodine-123 metaiodobenzylguanidine (123I-MIBG) myocardial scintigraphy has been used to evaluate cardiac sympathetic denervation in Lewy body disease (LBD), including Parkinson’s disease (PD) and dementia with Lewy bodies (DLB). The heart-tomediastinum ratio (H/M) in PD and DLB is significantly lower than that in Parkinson’s plus syndromes and Alzheimer’s disease. Although this ra...

متن کامل

Prediction of long-term cardiac events by 123I-MIBG imaging after acute myocardial infarction and reperfusion therapy

Objective(s): In heart failure, the heart-to-mediastinum (H/M) ratio of the delayed image and washout rate (WR) are well-known as a powerful cardiac event predictors. H/M ratio quantifies the accumulation rate of MIBG in the myocardium and WR quantifies reduction of meta-iodobenzylguanidine (MIBG) accumulation in the heart from the early planar image to the delayed pla...

متن کامل

A method of dynamic analysis of iodine-123-metaiodobenzylguanidine scintigrams in cardiac mechanical overload hypertrophy and failure.

Cardiac sympathetic neuronal degeneration accompanies mechanical overload heart failure. We hypothesized that sympathetic nerve and myocyte failure share a common etiology and that 123I-metaiodobenzylguanidine (MIBG) might provide a precise method of detecting failure in chronic mechanical overload. Our aim was to develop a method for the dynamic analysis of 123I-MIBG scintigrams which could yi...

متن کامل

Can combined assessment of baroreflex sensitivity and iodine-123 metaiodobenzylguanidine imaging be used for risk stratification of patients with type 2 diabetes mellitus?

he sympathetic nervous system of the heart is critically involved in the maintenance of cardiovascular homoeostasis by regulating cardiac contractility, conduction, heart frequency and peripheral vasoconstriction.1 It has been shown that a dysfunctional cardiac sympathetic nervous system exerts detrimental effects on the structural and functional integrity of the myocardium, leading to a marked...

متن کامل

Metaiodobenzylguanidine [131I] scintigraphy detects impaired myocardial sympathetic neuronal transport function of canine mechanical-overload heart failure.

In heart failure secondary to chronic mechanical overload, cardiac sympathetic neurons demonstrate depressed catecholamine synthetic and transport function. To assess the potential of sympathetic neuronal imaging for detection of depressed transport function, serial scintigrams were acquired after the intravenous administration of metaiodobenzylguanidine [131I] to 13 normal dogs, 3 autotranspla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 89 6  شماره 

صفحات  -