Increased organ sparing using shape-based treatment plan optimization for intensity modulated radiation therapy of pancreatic adenocarcinoma.

نویسندگان

  • Steven F Petit
  • Binbin Wu
  • Michael Kazhdan
  • André Dekker
  • Patricio Simari
  • Rachit Kumar
  • Russel Taylor
  • Joseph M Herman
  • Todd McNutt
چکیده

PURPOSE To develop a model to assess the quality of an IMRT treatment plan using data of prior patients with pancreatic adenocarcinoma. METHODS The dose to an organ at risk (OAR) depends in large part on its orientation and distance to the planning target volume (PTV). A database of 33 previously treated patients with pancreatic cancer was queried to find patients with less favorable PTV-OAR configuration than a new case. The minimal achieved dose among the selected patients should also be achievable for the OAR of the new case. This way the achievable doses to the OARs of 25 randomly selected pancreas cancer patients were predicted. The patients were replanned to verify if the predicted dose could be achieved. The new plans were compared to their original clinical plans. RESULTS The predicted doses were achieved within 1 and 2 Gy for more than 82% and 94% of the patients, respectively, and were a good approximation of the minimal achievable doses. The improvement after replanning was 1.4 Gy (range 0-4.6 Gy) and 1.7 Gy (range 0-6.3 Gy) for the mean dose to the liver and the kidneys, respectively, without compromising target coverage or increasing radiation dose to the bowel, cord or stomach. CONCLUSIONS The model could accurately predict the achievable doses, leading to a considerable decrease in dose to the OARs and an increase in treatment planning efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

متن کامل

Worst case optimization for interfractional motion mitigation in carbon ion therapy of pancreatic cancer

INTRODUCTION The efficacy of radiation therapy treatments for pancreatic cancer is compromised by abdominal motion which limits the spatial accuracy for dose delivery - especially for particles. In this work we investigate the potential of worst case optimization for interfractional offline motion mitigation in carbon ion treatments of pancreatic cancer. METHODS We implement a worst case opti...

متن کامل

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Direct Aperture Optimization for Intensity Modulated Radiation Therapy: Two Calibrated Metaheuristics and Liver Cancer Case Study

Integrated treatment planning for cancer patients has high importance in intensity modulated radiation therapy (IMRT). Direct aperture optimization (DAO) is one of the prominent approaches used in recent years to attain this goal. Considering a set of beam directions, DAO is an integrated approach to optimize the intensity and leaf position of apertures in each direction. In this paper, first, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology

دوره 102 1  شماره 

صفحات  -

تاریخ انتشار 2012