Note: Fast, small, accurate 90° rotator for a polarizer.

نویسندگان

  • David P Shelton
  • William M O'Donnell
  • James L Norton
چکیده

A permanent magnet stepper motor is modified to hold a dichroic polarizer inside the motor. Rotation of the polarizer by 90° ± 0.04° is accomplished within 80 ms. This device is used for measurements of the intensity ratio for two orthogonal linear polarized components of a light beam. The two selected polarizations can be rapidly alternated to allow for signal drift compensation, and the two selected polarizations are accurately orthogonal.

منابع مشابه

Intensity-Stabilized Fast-Scanned Direct Absorption Spectroscopy Instrumentation Based on a Distributed Feedback Laser with Detection Sensitivity down to 4 × 10−6

A novel, intensity-stabilized, fast-scanned, direct absorption spectroscopy (IS-FS-DAS) instrumentation, based on a distributed feedback (DFB) diode laser, is developed. A fiber-coupled polarization rotator and a fiber-coupled polarizer are used to stabilize the intensity of the laser, which significantly reduces its relative intensity noise (RIN). The influence of white noise is reduced by fas...

متن کامل

Polarization self-modulated lasers with circular eigenstates

A polarization self-modulated laser made of a semiconductor laser with an external cavity containing a Faraday rotator is investigated theoretically and experimentally. It is shown that the Faraday rotator yields circularly polarized eigenstates for the laser. Stable optical pulses at a frequency equal to one half of the free spectral range are observed through a polarizer, independently of the...

متن کامل

Characterization of bipartite states using a single homodyne detector

We suggest a scheme to reconstruct the covariance matrix of a two-mode state using a single homodyne detector plus a polarizing beam splitter and a polarization rotator. It can be used to fully characterize bipartite Gaussian states and to extract relevant information on generic states.

متن کامل

Characteristics of Rotator Cuff Repairs Revised to Shoulder Arthroplasty

Background: Successful repair of a torn rotator cuff may prevent progression to rotator cuff arthropathy. However,previous studies have shown a substantial rate of failure after rotator cuff repair and characteristics of surgicallyrepaired rotator cuffs that go on to shoulder arthroplasty have not been fully elucidated. The purpose of this study wasto determine the patient cha...

متن کامل

MR imaging of the rotator cuff.

MR imaging is the optimal method for evaluating suspected rotator cuff pathology. Current techniques of fast spin-echo imaging without and with fat suppression allow accurate identification and characterization of tendinous and myotendinous abnormalities of the rotator cuff. Impingement disorders, tendon degeneration, instability,and trauma comprise the multifactorial nature of rotator cuff dis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • The Review of scientific instruments

دوره 82 3  شماره 

صفحات  -