Field-scale evaluation of the passive flux meter for simultaneous measurement of groundwater and contaminant fluxes.

نویسندگان

  • Michael D Annable
  • Kirk Hatfield
  • Jaehyun Cho
  • Harald Klammler
  • Beth L Parker
  • John A Cherry
  • P Suresh C Rao
چکیده

A new method, passive flux meter (PFM), has been developed and field-tested for simultaneously measuring contaminant and groundwater fluxes in the saturated zone at hazardous waste sites. The PFM approach uses a sorptive permeable medium placed in either a borehole or monitoring well to intercept contaminated groundwater and release "resident" tracers. The sorbent pack is placed in a groundwater flow field for a specified exposure time and then recovered for extraction and analysis. By quantifying the mass fraction of resident tracers lost and the mass of contaminant sorbed, groundwater and contaminant fluxes are calculated. Here, we assessed the performance of PFMs at the Canadian Forces Base Borden field site in Ontario, Canada. Two field tests were conducted under imposed groundwater flow fields: (1) radial flow to a well and (2) linear flow in a test channel confined by sheet pile walls on three sides. Both tests demonstrate that the local fluxes measured by PFM and averaged overthe screen interval were within 15% of imposed groundwaterflow and within 30% of measured contaminant mass flux. Patterns in depth variations in groundwater and contaminant fluxes, determined by the PFM approach, allow for site characterization at a higher spatial resolution. These results support the PMF method as a potential innovative alternative for measuring groundwater and contaminant fluxes in screened wells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A direct passive method for measuring water and contaminant fluxes in porous media.

This paper introduces a new direct method for measuring water and contaminant fluxes in porous media. The method uses a passive flux meter (PFM), which is essentially a self-contained permeable unit properly sized to fit tightly in a screened well or boring. The meter is designed to accommodate a mixed medium of hydrophobic and/or hydrophilic permeable sorbents, which retain dissolved organic/i...

متن کامل

Magnitude and directional measures of water and Cr(VI) fluxes by passive flux meter.

A new configuration of the passive fluxmeter (PFM) is presented that provides for simultaneous measurements of both the magnitude and the direction of ambient groundwater specific discharge qo and Cr(VI) mass flux J(Cr). The PFM is configured as a cylindrical unit with an interior divided into a center section and three outer sectors, each packed with a granular anion exchange resin having high...

متن کامل

Evaluation and application of anion exchange resins to measure groundwater uranium flux at a former uranium mill site.

Laboratory tests and a field validation experiment were performed to evaluate anion exchange resins for uranium sorption and desorption in order to develop a uranium passive flux meter (PFM). The mass of uranium sorbed to the resin and corresponding masses of alcohol tracers eluted over the duration of groundwater installation are then used to determine the groundwater and uranium contaminant f...

متن کامل

Oxyanion flux characterization using passive flux meters: development and field testing of surfactant-modified granular activated carbon.

We report here on the extension of Passive Flux Meter (PFM) applications for measuring fluxes of oxyanions in groundwater, and present results for laboratory and field studies. Granular activated carbon, with and without impregnated silver (GAC and SI-GAC, respectively), was modified with a cationic surfactant, hexadecyltrimethylammonium (HDTMA), to enhance the anion exchange capacity (AEC). La...

متن کامل

Contaminant discharge and uncertainty estimates from passive flux meter measurements

[1] The passive flux meter (PFM) measures local cumulative water and contaminant fluxes at an observation well. Conditional stochastic simulation accounting for both spatial correlation and data skewness is introduced to interpret passive flux meter observations in terms of probability distributions of discharges across control planes (transects) of wells. An estimator of the effective number o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science & technology

دوره 39 18  شماره 

صفحات  -

تاریخ انتشار 2005