Measurement of heart rate variability using off-the-shelf smart phones
نویسندگان
چکیده
BACKGROUND The cardiac parameters, such as heart rate (HR) and heart rate variability (HRV), are very important physiological data for daily healthcare. Recently, the camera-based photoplethysmography techniques have been proposed for HR measurement. These techniques allow us to estimate the HR contactlessly with low-cost camera. However, the previous works showed limit success for estimating HRV because the R-R intervals, the primary data for HRV calculation, are sensitive to noise and artifacts. METHODS This paper proposed a non-contact method to extract the blood volume pulse signal using a chrominance-based method followed by a proposed CWT-based denoising technique. The R-R intervals can then be obtained by finding the peaks in the denoised signal. In this paper, we taped 12 video clips using the frontal camera of a smart phone with different scenarios to make comparisons among our method and the other alternatives using the absolute errors between the estimated HRV metrics and the ones obtained by an ECG-accurate chest band. RESULTS As shown in experiments, our algorithm can greatly reduce absolute errors of HRV metrics comparing with the related works using RGB color signals. The mean of absolute errors of HRV metrics from our method is only 3.53 ms for the static-subject video clips. CONCLUSIONS The proposed camera-based method is able to produce reliable HRV metrics which are close to the ones measured by contact devices under different conditions. Thus, our method can be used for remote health monitoring in a convenient and comfortable way.
منابع مشابه
Heart Rate Variability in an Elite Female Alpine Skier: a Case Study
Objectives. The purpose of this study was to assess the heart rate variability (HRV) during off-snow and on-snow training in an elite female alpine ski racer. Methods. Using a case study design, a single elite female alpine ski racer (25 years old; 175.6 cm; 69.9 kg) was recruited from the Canadian Alpine Ski Team. Training load was obtained using the sessional rating of perceived exertion met...
متن کاملAnalysis of Heart Rate Variability During Meditative and Non-Meditative State Using Analysis of Variance
In this paper the main objective is to quantify and compare the instantaneous value of heart rate for normal breathing patterns during Meditation and Non Meditation conditions. This paper involves Analysis of Variance (ANOVA) technique for the analysis of the heart rate variability patterns during the meditative and non meditative states. The analysis is divided into three stages i.e. data acqu...
متن کاملAnalysis of Heart Rate Variability During Meditative and Non-Meditative State Using Analysis of Variance
In this paper the main objective is to quantify and compare the instantaneous value of heart rate for normal breathing patterns during Meditation and Non Meditation conditions. This paper involves Analysis of Variance (ANOVA) technique for the analysis of the heart rate variability patterns during the meditative and non meditative states. The analysis is divided into three stages i.e. data acqu...
متن کاملMeasurement and Evaluation of the Autonomic Nervous Function in Daily Life
We developed a smart-phone based system to measure the activities of autonomic nervous system during everyday life. Using commonly marketed smart phones, by touching your fingertips on the phone’s camera over a short time of about 30 seconds, it will detect changes in the brightness of the blood flow and in turn analyze your heart rate variability. By using this system, about 100,000 cases were...
متن کاملTrial Results of a Novel Cardiac Rhythm Management System Using Smart Phones and Wireless ECG Sensors
This paper discusses the trial results of a personalised Cardiac Rhythm Management (CRM) system using a smart phone (PDA) and a wireless ECG sensor. The system is used in a trial to record and diagnose abnormal cardiac arrhythmias. This novel approach uses standard mobile phones, off-the-shelf ECG sensors and personalised feedback to the patient when compared to a conventional clinical Holter a...
متن کامل