Ultrahigh-contrast imaging by temporally modulated stimulated emission depletion.

نویسندگان

  • L V Doronina-Amitonova
  • I V Fedotov
  • A M Zheltikov
چکیده

Stimulated emission depletion (STED) is the key optical technology enabling super-resolution microscopy below the diffraction limit. Here, we demonstrate that modulation of STED in the time domain, combined with properly designed lock-in detection, can radically enhance the contrast of fluorescent images of strongly autofluorescent biotissues. In our experiments, the temporally modulated STED technique, implemented with low-intensity continuous-wave laser sources, is shown to provide an efficient all-optical suppression of a broadband fluorescent background, allowing the contrast of fluorescent images of mammal brain tissues tagged with nitrogen-vacancy diamond to be increased by five orders of magnitude.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stimulated Emission Depletion (STED) Microscopy: from Theory to Practice

In recent years, various methods have been proposed to increase the resolution of fluorescence microscopy beyond the diffraction limit of light. Amongst them, Stimulated Emission Depletion (STED) microscopy, which relies on a purely physical concept of fluorescence depletion could, in theory, achieve unlimited resolution independent of the wavelength of light. In this chapter, we review the fun...

متن کامل

Stimulated emission reduced fluorescence microscopy: a concept for extending the fundamental depth limit of two-photon fluorescence imaging

Two-photon fluorescence microscopy has become an indispensable tool for imaging scattering biological samples by detecting scattered fluorescence photons generated from a spatially confined excitation volume. However, this optical sectioning capability breaks down eventually when imaging much deeper, as the out-of-focus fluorescence gradually overwhelms the in-focal signal in the scattering sam...

متن کامل

Implementation of intensity-modulated laser diodes in time-resolved, pump-probe fluorescence microscopy.

We present the implementation of intensity-modulated laser diodes for applications in frequency-domain pump-probe fluorescence microscopy. Our technique, which is based on the stimulated-emission approach, uses two sinusoidally modulated laser diodes. One laser (635 nm) excites the chromophores under study, and the other laser (680 nm) is responsible for inducing stimulated emission from excite...

متن کامل

Optical Methods for Simultaneous Imaging and Stimulation of Neural Activity at Cellular Resolution in Awake, Behaving Mice

A central goal in neuroscience is to understand dynamics in the awake mammalian brain on a large scale that is also well-resolved (thousands of individual neurons). Recent optical methods for cellular-resolution fluorescence imaging using two-photon excitation (TPE) microscopy, or population-resolution optogenetic perturbation of activity, have been applied to measure or probe dynamics of neuro...

متن کامل

Coherent nonlinear optical imaging: beyond fluorescence microscopy.

The quest for ultrahigh detection sensitivity with spectroscopic contrasts other than fluorescence has led to various novel approaches to optical microscopy of biological systems. Coherent nonlinear optical imaging, especially the recently developed nonlinear dissipation microscopy (including stimulated Raman scattering and two-photon absorption) and pump-probe microscopy (including excited-sta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 40 5  شماره 

صفحات  -

تاریخ انتشار 2015