Clinical Performance of a Highly Cross-linked Polyethylene at 5 Years in Total Hip Arthroplasty: The Impact of Elliptical Distortion on a Clinical Wear Series

نویسندگان

  • John M. Martell
  • Jimmi Mangla
  • James Verner
  • Stephen J. Incavo
  • Chitranjan Ranawat
چکیده

Clinical Performance of a Highly Cross-linked Polyethylene at 5 Years in Total Hip Arthroplasty: The Impact of Elliptical Distortion on a Clinical Wear Series John M. Martell1, Jimmi Mangla1, James Verner2, Stephen J. Incavo3, Chitranjan Ranawat4 1The Department of Orthopaedics and Rehabilitation, Orthopaedic Biomedical imaging Institute, The University of Chicago, Chicago, IL; 2Department of Orthopaedics, William Beaumont Hospital, Royal Oak, MI; 3The Department of Orthopaedics, The Methodist Center for Orthopedic Surgery, Houston, TX; 4The Department of Orthopaedics, Lennox Hill Hospital, New York, NY [email protected]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo wear performance of highly cross-linked polyethylene vs. yttria stabilized zirconia and alumina stabilized zirconia at a mean seven-year follow-up

BACKGROUND Zirconia was introduced as an alternative to alumina for use in the femoral head. The yttria stabilized zirconia material was improved by adding alumina. We evaluated highly cross-linked polyethylene wear performance of zirconia in total hip arthroplasty. The hypothesis was that alumina stabilized zirconia could decrease highly cross-linked polyethylene wear. METHODS Highly cross-l...

متن کامل

A Multicenter Approach Evaluating the Impact of Vitamin E-Blended Polyethylene in Cementless Total Hip Replacement

Since polyethylene is one of the most frequently used biomaterials as a liner in total hip arthroplasty, strong efforts have been made to improve design and material properties over the last 50 years. Antioxidants seems to be a promising alternative to further increase durability and reduce polyethylene wear in long term. As of yet, only in vitro results are available. While they are promising,...

متن کامل

Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial

BACKGROUND Aseptic loosening of total hip arthroplasties is generally caused by periprosthetic bone resorption due to tissue reactions on polyethylene wear particles. In vitro testing of polyethylene cups incorporated with vitamin E shows increased wear resistance. The objective of this study is to compare vitamin E-stabilized highly cross-linked polyethylene with conventional cross-linked poly...

متن کامل

Total Hip Arthroplasty Using Metal Head on a Highly Cross-linked Polyethylene Liner

PURPOSE This retrospective study was performed to evaluate the clinical results and measure polyethylene liner wear in total hip arthroplasty (THA) with highly cross-linked polyethylene. MATERIALS AND METHODS Except for patients who had died or were unable to have follow-up at least 2 years, 60 of 78 hips that underwent THA were included this study. The mean age was 64.5 years (range, 25-81 y...

متن کامل

Wear Analysis of Second-generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty.

A major limiting factor in the longevity of total hip replacement is the wear rate of the hip bearing. As manufacturing technology has improved during the past several decades, much attention has been focused on developing newer generations of polyethylene that have lower rates of wear while minimizing free radical formation and subsequent osteolysis. The turning point for the manufacture of po...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002