The optimization of superficial planning target volumes (PTVs) with helical tomotherapy
نویسندگان
چکیده
When the planning target volume (PTV), extends close to or beyond the skin, inverse-planned intensity-modulated radiotherapy can boost the fluence from tan- gential angles to superficial parts of the PTV due to the buildup effect. This can result in significant regions of high dose upon a small movement in the patient's position. We analyzed different methods of reducing this effect in the TomoTherapy planning system, including using pretend bolus, clipping the PTV back from the skin surface, and combinations of both. No alternative technique was seen to be unconditionally superior to a 5 mm planning bolus. A clip distance of 3 mm gave acceptable results, but consideration should be given to the reduction in minimum dose or increase in maximum dose seen in clip distances just 1 mm less or more, respectively, when treating head and neck cases in TomoTherapy.
منابع مشابه
“The optimization of superficial planning target volumes (PTVs) with helical tomotherapy”. [JACMP, 15 (6), 2014]
This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. DOI: 10.1002/acm2.12117
متن کاملComparison of Helical Tomotherapy and Direct Tomotherapy in Bilateral Whole Breast Irradiation in a Case of Bilateral Synchronous Grade 1 and Stage 1 Breast Cancer
BACKGROUND Synchronous bilateral breast cancer is rare. A case is presented where whole breast irradiation (WBI) was planned after breast conserving surgery in a patient with synchronous bilateral breast cancer. A comparison was made between the feasibility of helical tomotherapy and direct tomotherapy. CASE REPORT A 60-year-old woman was found to have bilateral breast nodules on routine mammog...
متن کاملIndependent calculation of dose from a helical TomoTherapy unit
A new calculation algorithm has been developed for independently verifying doses calculated by the TomoTherapy Hi.Art treatment planning system (TPS). The algorithm is designed to confirm the dose to a point in a high dose, low dose-gradient region. Patient data used by the algorithm include the radiological depth to the point for each projection angle and the treatment sinogram file controllin...
متن کاملJunctioning longitudinally adjacent PTVs with Helical TomoTherapy
Irradiation of longitudinally adjacent PTVs with Helical TomoTherapy (HT) may be clinically necessary, for example in treating a recurrent PTV adjacent to a previously-treated volume. In this work, the parameters which influence the cumulative dose distribution resulting from treating longitudinally adjacent PTVs are examined, including field width, pitch, and PTV location. In-phantom dose dist...
متن کاملProstate Helical Tomotherapy: A semi-empirical estimation of the scaling factor based on 2D approximating field
Background: In Helical Tomotherapy (HT), the scaling factor (SF) is the time in seconds that each leaf viewing a target would need to be open to deliver the prescribed dose. The SF is patient-specific and is used to calculate the rotational period of the gantry, and the total treatment time (TTT) of the HT. The SF is generally difficult to estimate. Currently, it takes about one hour t...