Use of magnetic resonance angiography to select candidates with recently symptomatic carotid stenosis for surgery: systematic review.
نویسندگان
چکیده
OBJECTIVE To determine if sufficient evidence exists to support the use of magnetic resonance angiography as a means of selecting patients with recently symptomatic high grade carotid stenosis for surgery. DESIGN Systematic review of published research on the diagnostic performance of magnetic resonance angiography, 1990-9. MAIN OUTCOME MEASURES Performance characteristics of diagnostic test. RESULTS 126 potentially relevant articles were identified, but many articles failed to examine the performance of magnetic resonance angiography as a diagnostic test at the surgical decision thresholds used in major clinical trials on endarterectomy. 26 articles were included in a meta-analysis that showed a maximal joint sensitivity and specificity of 99% (95% confidence interval 98% to 100%) for identifying 70-99% stenosis and 90% (81% to 99%) for identifying 50-99% stenosis. Only four articles evaluated contrast enhanced magnetic resonance angiography. CONCLUSIONS Magnetic resonance angiography is accurate for selecting patients for carotid endarterectomy at the surgical decision thresholds established in the major endarterectomy trials, but the evidence is not very robust because of the heterogeneity of the studies included. Research is needed to determine the diagnostic performance of the most recent developments in magnetic resonance angiography, including contrast enhanced techniques, as well as to assess the impact of magnetic resonance angiography on surgical decision making and outcomes.
منابع مشابه
The cost-effectiveness of magnetic resonance angiography for carotid artery stenosis and peripheral vascular disease: a systematic review.
Printed copies of HTA monographs cost £20 each (post and packing free in the UK) to both public and private sector purchasers from our Despatch Agents. Non-UK purchasers will have to pay a small fee for post and packing. For European countries the cost is £2 per monograph and for the rest of the world £3 per monograph. You can order HTA monographs from our Despatch Agents: – fax (with credit ca...
متن کاملMeasuring carotid stenosis on contrast-enhanced magnetic resonance angiography: diagnostic performance and reproducibility of 3 different methods.
BACKGROUND AND PURPOSE The aim of this study was to compare diagnostic performance and reproducibility of 3 different methods of quantifying stenosis on contrast-enhanced magnetic resonance angiography (CEMRA), with intra-arterial digital subtraction angiography (DSA) as the reference standard. METHODS 167 symptomatic patients scheduled for DSA, after screening Doppler ultrasound, were prospe...
متن کاملBetween-method correlation in quantifying internal carotid stenosis.
BACKGROUND AND PURPOSE The degree of internal carotid stenosis has emerged as the most important predictor of ischemic stroke in extracranial carotid artery disease. The purpose of this study was to assess the validity of the noninvasive techniques for quantifying internal carotid stenosis with respect to the accepted standard of intra-arterial angiography. METHODS We measured the maximum per...
متن کاملComparison of magnetic resonance volume flow rates, angiography, and carotid Dopplers. Preliminary results.
BACKGROUND AND PURPOSE We compared the results of conventional angiography, carotid Doppler, and magnetic resonance angiography volume flow rates to determine the clinical utility of volume flow rate assessment of blood flow to the anterior circulation in patients with carotid occlusive disease. METHODS From 11 symptomatic patients, a total of 22 extracranial carotid arteries were studied wit...
متن کاملANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES
Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMJ
دوره 324 7331 شماره
صفحات -
تاریخ انتشار 2002