Effects of Systane® Balance on noninvasive tear film break-up time in patients with lipid-deficient dry eye

نویسندگان

  • Alejandro J Aguilar
  • Maria I Marquez
  • Paula A Albera
  • Jorge L Tredicce
  • Alejandro Berra
چکیده

PURPOSE To evaluate the ability of Systane(®) Balance (SYSB) administered four times per day for 4 weeks to increase noninvasive tear film break-up time (NITFBUT) over baseline compared with a saline (SAL) control in patients with lipid-deficient dry eye (DE). PATIENTS AND METHODS Patients aged ≥18 years with DE and evidence of meibomian gland dysfunction (ie, abnormal gland expression and missing meibomian glands) were included in this randomized, parallel-group, controlled, investigator-masked comparison study. Patients were randomized to SYSB or SAL four times daily for 4 weeks. The primary efficacy variable was mean change in NITFBUT from baseline at week 4. Ocular surface staining, goblet cell density, and meibomian gland expression were also assessed. Safety assessments included adverse events (AEs), best-corrected visual acuity, and ocular signs. RESULTS A total of 49 patients received study treatments (SYSB, n=25; SAL, n=24). Most patients were women (67.4%) and Caucasian (63.3%); mean ± standard deviation (SD) age was 44±19 years. DE characteristics at baseline were similar between groups. After 4 weeks of treatment, the mean ± SD NITFBUT increase from baseline was significantly greater with SYSB (2.83±0.74 seconds) compared with SAL (0.66±0.55 seconds; P<0.001, t-test). Improvements in conjunctival and corneal staining, percentage of patients with increased goblet cell density, and meibomian gland expression were also observed with 4 weeks of SYSB over SAL. No AEs were reported for either treatment group; best-corrected visual acuity and ocular signs remained stable or improved compared with baseline. CONCLUSION SYSB restored tear film stability, improved ocular surface healing, and improved meibomian gland functionality after 4 weeks of use in patients with lipid-deficient DE. No AEs were reported with either SYSB or SAL.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Systane® lubricant eye drops in the management of ocular dryness

The understanding of dry eye disease has advanced recently through increasing recognition that the etiology of the condition involves both tear evaporation and insufficient tear production, and that tear film instability and inflammation play roles in the various stages of the disease. Of significance, it has been recognized that lipid layer thickness correlates with tear film stability. The ma...

متن کامل

Novel formulation of glycerin 1% artificial tears extends tear film break-up time compared with Systane lubricant eye drops.

PURPOSE To evaluate the effectiveness of glycerin 1% formulated with the novel and proprietary ophthalmic excipient poly(l-lysine)-graft-poly(ethylene glycol) (PLL-g-PEG) (Eyeon Particle Sciences LLC) in extending tear film break-up time (TFBUT) compared with a market-leading artificial tear formulation of propylene glycol (0.3%) and polyethylene glycol (0.4%) (Systane(®) Lubricant Eye Drops; A...

متن کامل

Evaluation of clinical outcomes in patients with dry eye disease using lubricant eye drops containing polyethylene glycol or carboxymethylcellulose

BACKGROUND The purpose of this study was to compare changes in corneal staining in patients with dry eye after 6 weeks of treatment with Systane® Gel Drops or Refresh Liquigel® lubricant eye drops. METHODS Patients aged ≥18 years with a sodium fluorescein corneal staining sum score of ≥3 in either eye and best-corrected visual acuity of 0.6 logarithm of the minimum angle of resolution or bett...

متن کامل

The effect of low humidity on the human tear film.

PURPOSE To investigate the effect of exposure to a low relative humidity (RH) environment on tear film physiology. METHOD A controlled environment chamber was used to create 2 different environmental conditions. Ambient temperature was constant in both conditions (21°C) while the RH was set at 40% at the normal condition and at 5% in the desiccating environment. Tear evaporation, noninvasive ...

متن کامل

Tear Interferometric Patterns Reflect Clinical Tear Dynamics in Dry Eye Patients.

PURPOSE We investigated whether the tear interferometric pattern was able to identify differences in tear film kinetics among clinical subtypes of dry eye. METHODS A total of 138 eyes of 76 subjects (38 men and 38 women; mean age ± SD, 61.6 ± 16.2 years) with or without dry eye who visited Itoh Clinic from May to August 2015 were enrolled in a cross-sectional study. Clinical diagnosis of dry ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2014