Do PT and APTT sensitivities to factors' deficiencies calculated by the H47-A2 2008 CLSI guideline reflect the deficiencies found in plasmas from patients?

نویسندگان

  • M Martinuzzo
  • L Barrera
  • M Rodriguez
  • M A D'Adamo
  • M S López
  • J C Otaso
چکیده

INTRODUCTION Prothrombin time (PT) and activated partial thromboplastin time (APTT) sensitivity for detecting isolated factor deficiencies varies with different reagents and coagulometers. The Clinical and Laboratory Standards Institute (CLSI) H47A2 guideline proposed a method to calculate these sensitivities, but some inconsistency has been reported. This study aimed to calculate factor sensitivities using CLSI guideline and to compare them with those obtained from single factor-deficient patients' data. METHODS Different mixtures of normal pooled and deficient plasmas were prepared (<1IU/dL to 100 IU/dL) according to the CLSI H47A2 guideline. PT with rabbit brain (RB) and human recombinant (HR) thromboplastins, APTT and factors' activities were measured in an ACL TOP coagulometer. Sensitivities (maximum factor concentration that produces PT or APTT values out of the reference range) were calculated from mixtures and from patients with single-factor deficiencies: 17 factor FV, 36 FVII, 19 FX, 39 FVIII, 15 FIX 15 FXI and 24 FXII. RESULTS PT sensitivity with RB was as follows: FV 38 and 59, FVII 35 and 58, FX 56 and 64 IU/dL; PT sensitivity with HR was as follows: FV 39 and 45, FVII 51 and 50, FX 33 and 61 IU/dL; and APTT sensitivity was as follows: FV 39 and 45, FX 32 and 38, FVIII 47 and 60, FIX 35 and 44, FXI 33 and 43, FXII 37 and 46 IU/dL, respectively. CONCLUSIONS Reagent-coagulometer combination has adequate sensitivities to factor deficiencies according to guideline recommendations (>30 IU/dL). These should not be considered as actual sensitivities because those obtained by analysing patients' plasmas with single-factor deficiencies were higher for most factors and could induce misinterpretation of the basic coagulation test results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of APTT factor sensitivity – the misguiding guideline

INTRODUCTION The Clinical and Laboratory Standards Institute (CLSI) has produced a guideline detailing how to determine the activated partial thromboplastin time's (APTT) sensitivity to clotting factor deficiencies, by mixing normal and deficient plasmas. Using the guideline, we determined the factor sensitivity of two APTT reagents. METHODS APTTs were performed using Actin FS and Actin FSL o...

متن کامل

Analysis of the Operational Deficiencies Originating in Design at Wastewater Treatment Plants: A Case Study of the Islamic Republic of Iran

Considerable investments have been made in establishing wastewater treatment plants (WWTPs). However, evaluation of the performance of plants during recent years, when more WWTPs have become operational, shows that effluent quality criteria were not met in many instances. Preliminary assessment of the operational problems of WWTPs in Iran disclosed that numerous factors affect this issue of eff...

متن کامل

Critical aspects in routine coagulation testing

The major improvements obtained in the quality of commercial reagents and in the accuracy of coagulometers has rendered comparabilty of the results among different laboratories a major task of the bodies devoted to standardization of coagulation testing. Commutability of results is of major importance especially in the monitoring of anticoagulant therapy. Critical aspects relate to the preanaly...

متن کامل

اثر غلظت های مختلف ماده ضد انعقاد سیترات بر روی نتایج زمان پروترومبین (PT) و رمبوپلاستین نسبی (APTT) در بیماران آنمیک

Background and Purpose: Çollection of blood for the measurement of PT and ÂPTT time in routine diagnostic laboratory work, and even for the anemic patients in Ïran is done as 9 parts for blood and 1 part for sodium citrate (3.6%). While in some diagnostic lab kits and reference books, adjusted citrate volume with the value hematocrits (Hct) is recommended. Ïn this study a comparison between t...

متن کامل

The extent of deficiencies in the main forms of patients' medical records by the role of documentarians

Introduction: Despite the implementation of hospital information system, in some countries, medical records are still documented in traditional ways. Incomplete documentation in medical records can lead to inappropriate medical decisions and higher costs. The purpose of this study was to investigate the deficiencies of the main forms in medical records by the role of documentarians. Methods: T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of laboratory hematology

دوره 37 6  شماره 

صفحات  -

تاریخ انتشار 2015