Calculation of Dose Distribution and Dose Rate at Each Dwell Position in 60co Irradiator Svst-co-60/b in Vietnam
نویسنده
چکیده
---------------------------------------------------------------------***--------------------------------------------------------------------Abstract The dose distribution in irradiation room and the dose rate at each dwell position of 60Co irradiator SVST-Co-60/B have been calculated using MCNP code. The calculated results are useful information to estimate radiation safety and design irradiator, as well as to design the staying irradiation positions and process optimization.
منابع مشابه
Evaluation of dose distribution and dose gradient in brachytherapy cylindrical applicators using a dedicated Phantom for Iridium-192 and Cobalt-60 HDR sources
Introduction: A study was performed to evaluate radiation dose distribution and dose gradient around cylindrical applicators for high-dose-rate (HDR) brachytherapy systems with 192Ir, 60Co brachytherapy source applied for rectal and vaginal cancers treatments. Materials and Methods: Two additional computed tomography (CT) based plans were generated using a ...
متن کاملMonte Carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with Cobalt-60 sources
Background: In the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using Monte Carlo (MC) method. Materials and Methods: Two 60Co sources of GZP6 brachytherapy unit used for intracavitary treatments were simulated using MCNPX Monte Carlo code. Also the two types of colpostats including shielded and unshielded were simulated inside ...
متن کاملIndependent assessment of source transit time for the BEBIG SagiNova® high dose rate brachytherapy afterloader
Introduction: The dwell time and transit time components contribute to the overall delivered dose to patients in high dose rate (HDR) brachytherapy treatments. The transit time results from source entry and exit as well as source movements between dwell positions. It depends on various parameters such as the source speed profile, source indexer distance to dwell position, and ...
متن کاملDose profile modeling of the Gamma Irradiation Facility at Biotechnology and Nuclear Agriculture Research Institute of Ghana using MCNP5
Dose rates distribution through the 60 Co Gamma Irradiation Facility (GIF) at the Biotechnology and Nuclear Agriculture Research Institute (BNARI) was studied using the Monte Carlo code MCNP5. The MCNP5 code was used to model the GIF structure. The dose rates for selected dwell positions throughout the facility was calculated and analyzed. The absorbed dose rate distribution calculated ranged f...
متن کاملCalculation and Comparison of Heart Integral Dose in The Treatment of Esophagus Cancer with Three Photon Energies & Using CT Simulation and Treatment Planning System
Introduction: Esophageal cancer is one of the most frequently occurring cancers in Iran and having a high incidence rate among other countries. Radiotherapy is one of the three methods (surgery, radiotherapy and chemotherapy) for radical or palliative treatment of esophageal cancer. In this method of treatment, the organs such as heart and spinal cord are regarded as organs at r...
متن کامل