Myocardial perfusion scintigraphy to evaluate patients after coronary stent implantation.

نویسندگان

  • I Kósa
  • R Blasini
  • J Schneider-Eicke
  • F J Neumann
  • I Matsunari
  • J Neverve
  • A Schömig
  • M Schwaiger
چکیده

UNLABELLED Coronary stent implantation is an increasingly accepted revascularization method. The 20%-30% restenosis rate during the first 6 mo requires a close follow-up of the patients. Since there is very little data available defining the role of perfusion scintigraphy in the management of this population, the aim of this study was to assess the diagnostic performance of stress myocardial perfusion imaging for detecting restenosis in patients after coronary stent implantation. METHODS In 82 patients, 93 rest or stress SPECT studies were performed using 201Tl and 99mTc-hexakis-2-methoxyisobutyl isonitrile to evaluate 99 vascular territories with implanted coronary stents. The average interval between the stent implantation and the scintigraphic study was 210.5 +/- 129.6 days. The scintiscans were visually evaluated. A stress-induced perfusion defect with reversibility at rest was used as the criterion for stent restenosis. RESULTS Coronary angiography revealed a stenosis of > 50% diameter in the region of the stent in 19 arteries, while in 80 arteries there was no evidence of restenosis angiographically. With perfusion scintigraphy, 15/19 vascular territories with restenosed stents showed stress-induced perfusion abnormalities (sensitivity = 79%), while 62/80 territories without restenosis did not (specificity = 78%). In territories without a myocardial infarction (n = 48), sensitivity and specificity values were 8/8 (100%) and 36/44 (82%), and in territories with a myocardial infarction (n = 47) 7/11 (64%) and 26/36 (72%), respectively. Side branch stenosis was fairly frequent in patients without stent restenosis but with a reversible perfusion pattern on their scintiscan (8/18); however, these stenoses were induced infrequently by the stents (3 cases). CONCLUSION Using the criterion of defect reversibility, stress perfusion SPECT can accurately detect restenoses of coronary artery stents. This method is most accurate for evaluating patients without a previous myocardial infarction in the stented vascular territory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serial Myocardial Imaging after a Single Dose of Thallium-201

Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocar...

متن کامل

The first performance of myocardial perfusion scintigraphy, post intravenous Dipyridamole injection

SUMMARY Dipyridamolc-Thallium imaging is a relatively safe and accurate method to evaluate myocardial perfusion in patients who arc unable to exercise to a maximal exertion (5,6,8,9). A 51year-old woman was admitted to Taleghani hospital with clinical symptoms and signs of coronary artery disease. Intravenous dipyridamote-Thallium scan was performed in this case. In multiple views obtained f...

متن کامل

Evaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy

Introduction: The aim of this study was to evaluate the effect of successful kidney transplantation (KT) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-SPECT) in patients suffering from end-stage renal disease. ...

متن کامل

Frequency and clinical significance of myocardial ischemia detected early after coronary stent implantation.

UNLABELLED A high number (30%-50%) of reversible defects have been detected early after coronary balloon angioplasty. Inadequate luminal enlargement despite a good angiographic appearance has been suggested as a possible mechanism of these perfusion abnormalities, and some reports have shown better coronary flow reserve after coronary stent implantation than after balloon dilatation. The primar...

متن کامل

Effects of depression on myocardial perfusion scintigraphy [Persian]

  Introduction: The relationship between depression and coronary artery disease is well established; however assessment of this relationship using functional and semi-quantitative imaging (myocardial perfusion scintigraphy) was lacking. The aim of this study was to assess the relationship between the severity of depression and the severity of myocardial perfusion abno...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 39 8  شماره 

صفحات  -

تاریخ انتشار 1998