Assessing Test-retest Reliability of the Portable Brower Speed Trap Ii Testing System
نویسندگان
چکیده
The aim of the present study was to assess the test-retest reliability of the Brower Speed Trap II running speed timing system. The test-retest reliability of the system was assessed by testing 52 physical education students aged (±SD) 21.4 (±8.9) years. All participants were tested on 30-m sprint with 10-m, 20-m and 30-m split times. All measurements were obtained on two subsequent days. The results from this investigation indicate that the variations in the students’ performance between test day one and test day two was small and the intra-class correlation indicates a high repeatability. In the examination of the system reliability, the system did not show any marked systematic bias (p<.05) assessed by the paired sample t-test. However, the systematic bias and the random variation found indicate that the Brower Speed Trap II running speed timing system was a reliable testing instrument to be used in testing physical education students, and a useful instrument for measuring running speed. However, in future studies it would be interesting to examine if the system were able to monitor the small changes in running speed that could result from increasing the training of an already elite athlete. Furthermore, we concluded that if comparison of overall values of running speed is intended, it is advisable to use the same testing system, because different systems give different results based on the errors associated with it.
منابع مشابه
Agreement between the spatio-temporal gait parameters from treadmill-based photoelectric cell and the instrumented treadmill system in healthy young adults and stroke patients
BACKGROUND Treadmill gait analysis was more advantageous than over-ground walking because it allowed continuous measurements of the gait parameters. The purpose of this study was to investigate the concurrent validity and the test-retest reliability of the OPTOGait photoelectric cell system against the treadmill-based gait analysis system by assessing spatio-temporal gait parameters. MATERIAL...
متن کاملConcurrent Validity and Test-retest Reliability of the OPTOGait Photoelectric Cell System for the Assessment of Spatio-temporal Parameters of the Gait of Young Adults
[Purpose] The purpose of this study was to investigate the concurrent validity and test-retest reliability of the recently introduced OPTOGait Photoelectric Cell System for the assessment of spatio-temporal parameters of gait. [Subjects] Twenty healthy young adults (mean age = 27.35, SD = 7.4) were asked to walk 3 times on walkway at a comfortable speed. [Methods] Concurrent validity was assess...
متن کاملTest-retest reliability and validity of isometric knee-flexion and -extension measurement using 3 methods of assessing muscle strength.
CONTEXT Physicians and clinicians need portable, efficient, and cost-effective assessment tools to determine the effectiveness of rehabilitation programs after knee injury. Progress in rehabilitation should be evaluated using valid and reliable measurement methods. OBJECTIVE To examine the test-retest reliability of portable fixed dynamometry (PFD), handheld dynamometry (HHD), and isokinetic ...
متن کاملValidity and reliability of the Nintendo Wii Balance Board for assessment of standing balance.
Impaired standing balance has a detrimental effect on a person's functional ability and increases their risk of falling. There is currently no validated system which can precisely quantify center of pressure (COP), an important component of standing balance, while being inexpensive, portable and widely available. The Wii Balance Board (WBB) fits these criteria, and we examined its validity in c...
متن کاملReliability of a Novel Computerized Neuropsychological Battery for Mild Cognitive Impairment
Background. The NeuroTrax Mindstreams computerized cognitive assessment system was designed for widespread clinical and research use. A requirement for its use in longitudinal testing is demonstration of good test-retest reliability. To minimize practice effects, alternate forms of Mindstreams tests were administered on serial testing sessions. The present study evaluated the equivalence of the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012