SinoCor: motion correction in SPECT
نویسندگان
چکیده
Motion is a serious artifact in Cardiac nuclear imaging because the scanning operation takes a long time. Since reconstruction algorithms assume consistent or stationary data the quality of resulting image is affected by motion, sometimes significantly. Even after adoption of the gold standard MoCo(R) algorithm from Cedars-Sinai by most vendors, heart motion remains a significant challenge. Also, any serious study in quantitative analysis necessitates correction for motion artifacts. It is generally recognized that human eye is a very sensitive tool for detecting motion. However, two reasons prevent such manual correction: (1) it is costly in terms of specialist’s time, and (2) no such tool for manual correction is available currently. Previously, at SPIE-MIC’11, we presented a simple tool (SinoCor) that allows sinograms to be corrected manually or automatically. SinoCor performs correction of sinograms containing inter-frame patient or respiratory motions using rigid-body dynamics. The software is capable of detecting the patient motion and estimating the body-motion vector using scanning geometry parameters. SinoCor applies appropriate geometrical correction to all the frames subsequent to the frame when the movement has occurred in a manual or automated mode. For respiratory motion, it is capable of automatically smoothing small oscillatory (frame-wise local) movements. Lower order image moments are used to represent a frame and the required rigid body movement compensation is computed accordingly. Our current focus is on enhancement of SinoCor with the capability to automatically detect and compensate for intra-frame motion that causes motion blur on the respective frame. Intra-frame movements are expected in both patient and respiratory motions. For a controlled study we also have developed a motion simulator. A stable version of SinoCor is available under license from Lawrence Berkeley National Laboratory.
منابع مشابه
اصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدلسازی منحنی چند جمله ای
Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...
متن کاملAssessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]
Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...
متن کاملValue of automatic patient motion detection and correction in myocardial perfusion imaging using a CZT-based SPECT camera
BACKGROUND Correction of motion has become feasible on cadmium-zinc-telluride (CZT)-based SPECT cameras during myocardial perfusion imaging (MPI). Our aim was to quantify the motion and to determine the value of automatic correction using commercially available software. METHODS AND RESULTS We retrospectively included 83 consecutive patients who underwent stress-rest MPI CZT-SPECT and invasiv...
متن کاملA flexible multicamera visual-tracking system for detecting and correcting motion-induced artifacts in cardiac SPECT slices.
Patient motion is inevitable in SPECT and PET due to the lengthy period of time patients are imaged. The authors hypothesized that the use of external-tracking devices which provide additional information on patient motion independent of SPECT data could be employed to provide a more robust correction than obtainable from data-driven methods. Therefore, the authors investigated the Vicon MX vis...
متن کاملEvaluation of attenuation correction process in cardiac SPECT images
Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...