High fidelity medical simulation in the difficult environment of a helicopter: feasibility, self-efficacy and cost

نویسندگان

  • Stewart W Wright
  • Christopher J Lindsell
  • William R Hinckley
  • Annette Williams
  • Carolyn Holland
  • Christopher H Lewis
  • Gail Heimburger
چکیده

BACKGROUND This study assessed the feasibility, self-efficacy and cost of providing a high fidelity medical simulation experience in the difficult environment of an air ambulance helicopter. METHODS Seven of 12 EM residents in their first postgraduate year participated in an EMS flight simulation as the flight physician. The simulation used the Laerdal SimMantrade mark to present a cardiac and a trauma case in an EMS helicopter while running at flight idle. Before and after the simulation, subjects completed visual analog scales and a semi-structured interview to measure their self-efficacy, i.e. comfort with their ability to treat patients in the helicopter, and recognition of obstacles to care in the helicopter environment. After all 12 residents had completed their first non-simulated flight as the flight physician; they were surveyed about self-assessed comfort and perceived value of the simulation. Continuous data were compared between pre- and post-simulation using a paired samples t-test, and between residents participating in the simulation and those who did not using an independent samples t-test. Categorical data were compared using Fisher's exact test. Cost data for the simulation experience were estimated by the investigators. RESULTS The simulations functioned correctly 5 out of 7 times; suggesting some refinement is necessary. Cost data indicated a monetary cost of 440 dollars and a time cost of 22 hours of skilled instructor time. The simulation and non-simulation groups were similar in their demographics and pre-hospital experiences. The simulation did not improve residents' self-assessed comfort prior to their first flight (p > 0.234), but did improve understanding of the obstacles to patient care in the helicopter (p = 0.029). Every resident undertaking the simulation agreed it was educational and it should be included in their training. Qualitative data suggested residents would benefit from high fidelity simulation in other environments, including ground transport and for running codes in hospital. CONCLUSION It is feasible to provide a high fidelity medical simulation experience in the difficult environment of the air ambulance helicopter, although further experience is necessary to eliminate practical problems. Simulation improves recognition of the challenges present and provides an important opportunity for training in challenging environments. However, use of simulation technology is expensive both in terms of monetary outlay and of personnel involvement. The benefits of this technology must be weighed against the cost for each institution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تاثیر روانی- عاطفی شبیه سازها در آموزش دانشجویان کارشناسی پرستاری : یک مطالعه مروری نظام مند

Introduction: High-Fidelity simulators are considered as costly educational technologies. With a cost-effective view, if this technology can be an effective and profound impact on learners may be considered as a good alternative and complementary option to theoretical and clinical nursing education.  But if the effects of this technology haven’t appropriate depth, it should paid spec...

متن کامل

tudy of Clinical Self-efficacy and belongingness to Clinical Environment in Undergraduate Nursing Students of Razi School of Nursing and Midwifery, Kerman University of Medical Sciences

Introduction: Identification and evaluation of  principal of self efficacy and clinical belonginess can be helpful to improve professional values and practice of the clinical environment. Methods: This study is a cross-sectional descriptive-analytic one, 230 students participated as research sample. Data were collected using a questionnaire consisting of three parts,  demographic information f...

متن کامل

Relationship between clinical environment stressors and nursing students self-efficacy in clinical performance

Introduction: Clinical education is the essential part of medical sciences which is necessary to raise competent professionals. Nursing students are confronted with a lot of stressors specialy in their clinical education. These stressors can interfere with improving competency and self-efficacy in nursing students. So we decided to investigate the relationship between clinical education stresso...

متن کامل

The Effect of Computer Simulation and Mannequin on Nursing Students’ Perception of Self-efficacy in Cardiopulmonary Resuscitation

Introduction: Resuscitation self-efficacy is defined as a judgment of perceived capability to organize and execute the process of care during cardiopulmonary resuscitation. It is believed to be an important factor in teaching vital nursing skills especially cardiopulmonary resuscitation. Therefore, this study aimed to investigate the impact of mannequin-based simulation and computer-based simul...

متن کامل

Intelligent Auto pilot Design for a Nonlinear Model of an Autonomous Helicopter by Adaptive Emotional Approach

There is a growing interest in the modeling and control of model helicopters using nonlinear dynamic models and nonlinear control. Application of a new intelligent control approach called Brain Emotional Learning Based Intelligent Controller (BELBIC) to design autopilot for an autonomous helicopter is addressed in this paper. This controller is applied to a nonlinear model of a helicopter. This...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Medical Education

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2006