New type of antidrying lens for vitreous surgery with a noncontact wide-angle viewing system

نویسندگان

  • Tomoyuki Chihara
  • Mihori Kita
چکیده

Drying of the cornea during surgery, which causes poor visibility of the fundus, is one of the more serious problems when using a noncontact type wide-angle viewing system. We developed an antidrying corneal contact lens for use with this type of viewing system. The lens has a very thin meniscus made of polymethyl methacrylate with a large outer diameter. Following application of the viscoelastic material, the lens can be put on the cornea without using a contact lens fixation ring. The larger diameter and lightweight characteristics of our lens contributed to its overall stability. The smooth surface of this prototype lens was able to achieve an intraoperative view of good quality, not only by preventing the cornea from drying, but also by providing a smooth surface over the entire cornea.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined use of high-reflective index vitrectomy meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery

BACKGROUND The aim of this study was to assess the combined use of a high-reflective index vitrectomy (HHV) meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery. METHODS Twenty-three gauge vitrectomy was performed with combined use of a HHV meniscus contact lens and a noncontact wide-angle viewing system. When delicate manipulation of the retina such as interna...

متن کامل

A new lens for observing fundus with a noncontact wide-angle viewing system

Drying of the cornea during surgery, which causes poor visibility of the fundus, is one of the most serious problems when using a noncontact-type wide-angle viewing system. This study used a newly commercialized lens for observing the fundus with a noncontact wide-angle viewing system. The lens used has a very thin meniscus made of polymethyl methacrylate and a large outer diameter. Following t...

متن کامل

Scleral buckling for primary rhegmatogenous retinal detachment using noncontact wide-angle viewing system with a cannula-based 25 G chandelier endoilluminator

PURPOSE To assess the outcome of scleral buckling surgery using a noncontact wide-angle viewing system for fundus visualization in patients with rhegmatogenous retinal detachment. METHODS Twenty-eight eyes of 28 patients underwent a modified scleral buckling surgery using a noncontact wide-angle viewing system combined with a 27-gauge optic fiber inserted into the sclera at the pars plana thr...

متن کامل

Hybrid wide-angle viewing-endoscopic vitrectomy using a 3D visualization system

Purpose To introduce a hybrid wide-angle viewing-endoscopic vitrectomy, which we have reported, using a 3D visualization system developed recently. Subjects and methods We report a single center, retrospective, consecutive surgical case series of 113 eyes that underwent 25 G vitrectomy (rhegmatogenous retinal detachment or proliferative vitreoretinopathy, 49 eyes; epiretinal membrane, 18 eyes...

متن کامل

Scleral buckling procedure with chandelier illumination for pediatric rhegmatogenous retinal detachment

PURPOSE To assess the treatment of pediatric patients with rhegmatogenous retinal detachment (RRD) by scleral buckling with chandelier illumination. METHODS Three eyes were treated in three patients, healthy boys aged 7 years, 12 years, and 11 years, with RRD, macular involvement, and small retinal holes, of which two were preoperatively undetectable. Conventional scleral buckling with cryore...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013