Detection of deterioration or infection of homograft and porcine xenograft bioprosthetic valves in mitral and aortic positions by two-dimensional echocardiographic examination.

نویسندگان

  • E Grenadier
  • D J Sahn
  • A H Roche
  • L M Valdes-Cruz
  • J G Copeland
  • S J Goldberg
  • H D Allen
چکیده

Results of two-dimensional echocardiographic examinations were compared with angiographic, hemodynamic and surgical results in 44 patients with bioprosthetic valves in mitral and aortic positions who were undergoing elective or urgent reinvestigation 24 to 87 months (mean 34) after implantation. In these patients, there were 18 homograft aortic valves in the aortic position, 9 stent-mounted homograft aortic valves in the mitral position, 13 porcine xenograft valves in the mitral position and 12 in the aortic position. Poor cusp support, gross fluttering and prolapse of cusps behind or below the anulus identified aortic insufficiency by two-dimensional echocardiography in six patients with an aortic homograft and four patients were identified with insufficiency of a stent-mounted aortic homograft in the mitral position. Two-dimensional echocardiographic examination revealed mitral stenosis in three patients with a porcine xenograft valve in the mitral position and suggested mitral insufficiency in two others. Bacterial endocarditis on homograft or porcine xenograft valves was associated with easily imaged vegetations by two-dimensional echocardiography in 10 patients. Despite difficulties in imaging valve cusps, and the skill required to obtain good echocardiographic images of bioprosthetic valves, significant valve deterioration or infected prostheses were quite effectively imaged by two-dimensional echocardiography in this study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term Doppler echocardiographic results of aortic or mitral valve replacement with Biocor porcine bioprosthesis.

OBJECTIVES Our objectives were to evaluate the long-term bioprosthetic and cardiac functional outcome after insertion (over a 10-year period) of a new-generation porcine zero pressure-fixed Biocor bioprosthesis, as well as to determine the echocardiographic accuracy for selection of patients requiring reoperation. The long-term systematic Doppler echocardiographic assessment after valve replace...

متن کامل

Non-invasive assessment by Doppler ultrasound of 155 patients with bioprosthetic valves: a comparison of the Wessex porcine, low profile Ionescu-Shiley, and Hancock pericardial bioprostheses.

One hundred and fifty five patients with 167 bioprosthetic valves (68 Wessex porcine, 54 Hancock pericardial, and 45 low profile Ionescu-Shiley pericardial valves) were studied by Doppler ultrasound. Valve gradients were calculated from the mitral and aortic flow velocities by the modified Bernoulli equation. Mean mitral gradients were significantly smaller across the Ionescu-Shiley valves than...

متن کامل

Echocardiographic changes in the thickness of porcine valves with time.

To assess the ability of M-mode echocardiography to detect the incidence and frequency of porcine xenograft valve thickening, echocardiograms were obtained in 147 mitral and aortic porcine xenograft valves implanted in 131 patients. The patients were divided into an early group in whom the echocardiograms were performed within two months of valve replacement, and intermediate group studied two ...

متن کامل

Degenerative processes in bioprosthetic mitral valves in juvenile pigs

BACKGROUND Glutaraldehyde-treated bioprosthetic heart valves are commonly used for replacement of diseased heart valves. However, calcification and wear limit their durability, and the development of new and improved bioprosthetic valve designs is needed and must be evaluated in a reliable animal model. We studied glutaraldehyde-treated valves 6 months after implantation to evaluate bioprosthet...

متن کامل

Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.

We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 2 3  شماره 

صفحات  -

تاریخ انتشار 1983