Influence of higher valve gradient on long-term outcome after aortic valve repair.

نویسندگان

  • Hunaid A Vohra
  • Robert N Whistance
  • Laurent de Kerchove
  • David Glineur
  • Philipe Noirhomme
  • Gebrine El Khoury
چکیده

BACKGROUND To evaluate the effect of higher post-operative valve gradient on freedom from valve re-intervention and death in patients undergoing aortic valve repair (AVr). METHODS Patients who underwent AVr between March 1996 and June 2010 were divided into 2 groups: I: peak gradient (PG) <20 mmHg (n=358) and II: PG ≥20 mmHg (n=113). Age (53.6±16.0 vs. 50.6±16.4 years; P=0.08), impaired LV (n=44, 12.2% vs. n=12, 10.6%: P=0.73) as well as the body surface area (1.97 vs. 1.95 m(2); P=0.4) were similar. Pre-operative AI >2+ was greater in Group II compared to Group I (n=78, 69.0% vs. n=192, 53.6%; P=0.004). Patients in Group II had higher proportion of bicuspid valves (BV) (n=58, 51.3% vs. n=106, 29.6%; P=0.0001) and restrictive valves (n=34, 30.0% vs. n=52, 14.5%; P=0.0001) while Marfan patients were seen only in Group I (n=19; P=0.010). Mean follow-up for Group I and Group II was 123.1±89.7 and 147.1±108.0 months, respectively. RESULTS In-hospital mortality was n=2 (0.5%) for Group I and none for Group II (P=1.0). Valve-sparing was higher in Group I (P=0.0001) but sub-commissural annuloplasty was similar (P=0.15). Shaving and/or decalcification was performed more in Group II (n=68, 60.1% vs. n=117, 32.6%; P=0.0001). Logistic regression analysis identified calcified, restrictive and bicuspid valves as independent predictors of PG ≥20 mmHg (P=0.04 for each). Predictors of re-operation were increased end-diastolic diameter (P=0.03) and younger age (P=0.007), but not PG ≥20 mmHg (P=0.98) (based on logistic regression). Overall 10-year cardiac survival and freedom from AV re-intervention was 82.3±4.6% vs. 89.5±4.2% (P=0.53) and 89.1±3.0% vs. 76.8±8.4% (P=0.02), in Group I and II, respectively (based on Kaplan-Meier analysis). Sub-group analysis showed that Group II patients requiring re-intervention (n=10) were younger (41.8±13.1 vs. 51.0±16.0 years; P=0.08) with similar proportion of bicuspid valves (n=6; 60%; P=0.74). The main reason for AV re-operation was aortic insufficiency (n=7) and AI + stenosis (n=3). CONCLUSIONS Higher gradient after AVr is associated with a reduced freedom from AV re-intervention, especially in younger patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful Repair of Type a Aortic Dissection in a Term Pregnancy: A Case Report

Stanford type A acute aortic dissection (AAD) is a very rare complication, with potentially lethal consequences in pregnancy. In fact, pregnancy has been regularly associated with the possibility of aortic. dissection in almost half of young women. Herein, we present the case of a 38-year-old woman in her 37th week of pregnancy. The patient’s medical history was indicative of G4L2Ab1(4 gestaiti...

متن کامل

SHORT TERM CLINICAL OUTCOME OF PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY VERSUS SURGICAL CLOSED MITRAL COMMISSUROTOMY

BaIlon mitral valvuloplasty and closed mitral valve conunissurotomy were performed in 450 and 127 patients, respectively. Also, 254 patients with severe mitral stenosis were enrolled in a prospective randomized trial comparing the two procedures. Immediately after balloon mitral valvuloplasty, mean left atrial pressure was 11.38±3.54 mmHg, transmitral valve gradient was 1.8±2 mmHg, and mit...

متن کامل

Main indications and long-term outcomes of reoperation after initial repair of tetralogy of Fallot

Background and Objective: The aim of this study was to analyze our indications, surgical procedures, and clinical outcomes of patients undergoing reoperation after surgical correction of tetralogy of Fallot (TOF). Methods: Thirty seven consecutive patients who underwent reoperation late after intra-cardiac repair of TOF within a period of 10 years were assessed. Results: The most co...

متن کامل

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

Three Different Imaging Modalities of a Patient with the Aortic Coarctation

The patient was a 19 year-old woman with the diagnosis of resistant hypertension, although she was under treatment of three classes of anti-hypertensive drugs (beta blocker, angiotensin receptor blocker, diuretic) for more than one year. In physical examination there was only a significant difference between the systolic blood pressure of upper and lower extremities (200 vs. 120 mmHg), without ...

متن کامل

Doppler echocardiographic findings in tissue engineered aortic valve in a sheep model

Background: Heart valve diseases are considered a common disease in human and animals, and valve replacement is an option for treatment of valvular diseases. Objectives: In this study efficacy of a tissue engineered valve in thoracic aorta was evaluated with transthoracic echocardiography. Methods: This study was undertaken on 6 male sheep. Echocardiography was performed on all sheep 24 hours b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of cardiothoracic surgery

دوره 2 1  شماره 

صفحات  -

تاریخ انتشار 2013