Emergent stabilization of pelvic ring injuries by controlled circumferential compression: a clinical trial.

نویسندگان

  • James C Krieg
  • Marcus Mohr
  • Thomas J Ellis
  • Tamara S Simpson
  • Steven M Madey
  • Michael Bottlang
چکیده

BACKGROUND Pelvic ring injuries are associated with a high incidence of mortality mainly due to retroperitoneal hemorrhage. Early stabilization is an integral part of hemorrhage control. Temporary stabilization can be provided by a pelvic sheet, sling, or an inflatable garment. However, these devices lack control of the applied circumferential compression. We evaluated a pelvic circumferential compression device (PCCD), which allows for force-controlled circumferential compression. In a prospective clinical trial, we documented how this device can provide effective reduction of open-book type pelvic injuries without causing overcompression of lateral compression type injuries. METHODS Sixteen patients with pelvic ring injuries were enrolled. Pelvic fractures were temporarily stabilized with a PCCD until definitive stabilization was provided. Anteroposterior pelvic radiographs were obtained before and after PCCD application, and after definitive stabilization. These radiographs were analyzed to quantify pelvic reduction due to the PCCD in comparison to the quality of reduction after definitive stabilization. Results were stratified into external rotation and internal rotation fracture patterns. RESULTS In the external rotation group, the PCCD significantly reduced the pelvic width by 9.9 +/- 6.0%. This reduction closely approximated the 10.0 +/- 4.1% reduction in pelvic width achieved by definitive stabilization. In the internal rotation group, the PCCD did not cause significant overcompression. No complications were observed. CONCLUSIONS A PCCD can effectively reduce pelvic ring injuries. It poses a minimal risk for overcompression and complications as compared with reduction alternatives that do not provide a feedback on the applied reduction force.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pelvic circumferential compression in the presence of soft-tissue injuries: a case report.

Unstable pelvic ring disruptions are frequently associated with hemodynamic instability. Although the source of hemorrhage can be from multiple sites, the severity and type of pelvic disruption strongly correlates with retroperitoneal blood loss. Pelvic stabilization in the early posttraumatic phase is reported to provide an effective means of controlling this retroperitoneal hemorrhage. Pelvic...

متن کامل

Noninvasive reduction of open-book pelvic fractures by circumferential compression.

OBJECTIVES To determine the efficacy and optimal application parameters of circumferential compression to reduce external rotation-type pelvic fractures. DESIGN Biomechanical investigation on human cadaveric specimens. SETTING Biomechanics laboratory. INTERVENTION Partially stable and unstable external rotation injuries of the pelvic ring (OTA classification 61-B1 and 61-C1) were created ...

متن کامل

The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

 Abstract Background: Unstable Pelvic fracture, a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This st...

متن کامل

Stabilization of pelvic ring disruptions with a circumferential sheet.

Pelvic ring disruptions in the polytraumatized patient are associated with a mortality rate of up to 25%.1 Acute uncontrolled hemorrhage and its complications are the leading causes of death in these patients.2 Treatment algorithms for resuscitation and control of hemorrhage are aimed at reducing morbidity and mortality. Although variations exist among these algorithms, essentially all include ...

متن کامل

Application of Circumferential Compression Device (Binder) in Pelvic Injuries: Room for Improvement

INTRODUCTION The use of a noninvasive pelvic circumferential compression device (PCCD) to achieve pelvic stabilization by both decreasing pelvic volume and limiting inter-fragmentary motion has become commonplace, and is a well-established component of Advanced Trauma Life Support (ATLS) protocol in the treatment of pelvic ring injuries. The purpose of this study was to evaluate the following: ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of trauma

دوره 59 3  شماره 

صفحات  -

تاریخ انتشار 2005