Preparation of Reference Material 8504, Transformer Oil
نویسندگان
چکیده
A new reference material (RM), RM 8504, has been prepared for use as a diluent oil with Aroclors in transformer oil Standard Reference Materials (SRMs) 3075 to 3080 and SRM 3090 when developing and validating methods for the determination of polychlorinated biphenyls (PCBs) as Aroclors in transformer oil or similar matrices. SRMs 3075-3080 and SRM 3090 consist of individual Aroclors in the same transformer oil that was used to prepare RM 8504. A unit of RM 8504 consists of one bottle containing approximately 100 mL of transformer oil. No additional constituents have been added to the oil.
منابع مشابه
An Investigation on Stability, Electrical and Thermal Characteristics of Transformer Insulting Oil Nanofluids
Transformer insulating oil nanofluid is made to improve dielectric and thermal properties of the oil by employing nanoparticles with proper properties. In the current work, nanofluids based on transformer mineral oil were prepared by three procedures using diamond nanoparticles with high thermal conductivity, as well as high dielectric properties. It was tried to consider the impacts of surfact...
متن کاملElectrical and Thermal investigation of Transformer Oil base Nanofluids
Transformer oil is one of the most important materials which are used in electrical and transformer industrial. The main function is protection and insulation of transformer core components, as well as heat transfer from its core to environment. Improving the performance of this material has been one of the researchers' concerns. The effect of different nanoparticle on the electrical breakdown ...
متن کاملStandard Reference Materials (SRMs) for the Calibration and Validation of Analytical Methods for PCBs (as Aroclor Mixtures)
Six Standard Reference Materials (SRMs®) have been prepared by the National Institute of Standards and Technology (NIST) for the determination of PCBs as different Aroclor mixtures in methanol. Six additional SRMs of the same Aroclors in transformer oil have also been prepared. Specifically, solutions of Aroclors 1016, 1232, 1242, 1254, and 1260 have been gravimetrically prepared (individually)...
متن کاملInvestigating the Transformer Operating Conditions for Evaluating the Dielectric Response
This paper presents an experimental investigation of transformer dielectric response and solid insulation water content. The dielectric response was carried out on the base of Hybrid Frequency Dielectric Spectroscopy and Polarization Current measurements method (FDS &PC). The calculation of the water content in paper is based on the water content in oil and the obtained equilibrium curves. A re...
متن کاملNondestructive and Noncontact Dielectric Measurement Methods for Transformer Oil Using Free-space Microwave Measurement System in 19 – 25 GHz Frequency Range
Nondestructive, noncontact and real time evaluation of dielectric properties of low-loss liquids are important for applications such as service-aged transformer oil, biomedical, remote sensing and design of radar absorbing material. Free-space methods were developed to measure dielectric properties of low-loss liquids at microwave frequencies. Metal-back method was developed for Freespace Micro...
متن کامل