Novel flowcytometry-based approach of malignant cell detection in body fluids using an automated hematology analyzer

نویسندگان

  • Tomohiko Ai
  • Yoko Tabe
  • Hiroyuki Takemura
  • Konobu Kimura
  • Toshihiro Takahashi
  • Haeun Yang
  • Koji Tsuchiya
  • Aya Konishi
  • Kinya Uchihashi
  • Takashi Horii
  • Akimichi Ohsaka
چکیده

Morphological microscopic examinations of nucleated cells in body fluid (BF) samples are performed to screen malignancy. However, the morphological differentiation is time-consuming and labor-intensive. This study aimed to develop a new flowcytometry-based gating analysis mode "XN-BF gating algorithm" to detect malignant cells using an automated hematology analyzer, Sysmex XN-1000. XN-BF mode was equipped with WDF white blood cell (WBC) differential channel. We added two algorithms to the WDF channel: Rule 1 detects larger and clumped cell signals compared to the leukocytes, targeting the clustered malignant cells; Rule 2 detects middle sized mononuclear cells containing less granules than neutrophils with similar fluorescence signal to monocytes, targeting hematological malignant cells and solid tumor cells. BF samples that meet, at least, one rule were detected as malignant. To evaluate this novel gating algorithm, 92 various BF samples were collected. Manual microscopic differentiation with the May-Grunwald Giemsa stain and WBC count with hemocytometer were also performed. The performance of these three methods were evaluated by comparing with the cytological diagnosis. The XN-BF gating algorithm achieved sensitivity of 63.0% and specificity of 87.8% with 68.0% for positive predictive value and 85.1% for negative predictive value in detecting malignant-cell positive samples. Manual microscopic WBC differentiation and WBC count demonstrated 70.4% and 66.7% of sensitivities, and 96.9% and 92.3% of specificities, respectively. The XN-BF gating algorithm can be a feasible tool in hematology laboratories for prompt screening of malignant cells in various BF samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of the Cell-Dyn Sapphire hematology analyzer for automated counting of blood cells in body fluids.

The enumeration and identification of blood cells in body fluids offers important information for the diagnosis and treatment of various medical conditions. Manual microscopic methods (hemacytometer total cell count and cytocentrifuged differential count) have inherent analytic and economic disadvantages but are still considered the "gold standard" methods. We evaluated the analytic and clinica...

متن کامل

A multicenter evaluation of the Iris iQ200 automated urine microscopy analyzer body fluids module and comparison with hemacytometer cell counts.

Manual hemacytometer cell counting of body fluids is labor-intensive and requires skilled testing personnel. We performed a multicenter evaluation of the Iris iQ200 automated microscopy analyzer Body Fluids Module (Iris Diagnostics, Chatsworth, CA) and compared 350 iQ200 body fluid cell counts with manual hemacytometer cell counts. Within-run imprecision, expressed as coefficient of variation (...

متن کامل

Performance evaluation of the ADVIA 2120 hematology analyzer: an international multicenter clinical trial.

Automated cell counters are widely used in modern clinical laboratories to provide reliable, fast, and cost-effective complete blood counts (CBCs), white blood cell differentials, and reticulocyte measurements. In addition, some advanced instruments provide novel parameters, such as the hemoglobin content of reticulocytes or the percentage of hypochromic cells, and are capable of analysis of a ...

متن کامل

Evaluation of pleural and ascitic fluid analysis on the Sysmex XE-5000 hematology analyzer

Introduction: Body fluid (BF) analysis is critical to the diagnosis and monitoring of several pathological conditions. The limitations of manual cell counts have led to greater interest in the development of automated BF analysis. Objective: To evaluate the analytical performance of the Sysmex XE-5000 hematology analyzer in the analysis of pleural and ascitic fluids in the laboratory routine of...

متن کامل

Detecting human CD34+ and CD34- hematopoietic stem and progenitor cells using a Sysmex automated hematology analyzer.

In clinical medicine, particularly in the newly developing stem cell therapies required to support the practice of regenerative medicine, the measurement of both CD34+ and CD34- hematopoietic stem cells (HSC)/hematopoietic progenitor cells (HPC) is important in obtaining more accurate information about the total HSC/HPC content in various stem/progenitor cell sources. We report the results of a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -