Quadriceps force after TKA with femoral single radius

نویسندگان

  • Sven Ostermeier
  • Christina Stukenborg-Colsman
چکیده

BACKGROUND AND PURPOSE New implant designs have incorporated a single radius instead of a multiple radius to the femoral component in order to improve the mechanical function after TKA. We investigated the amount of quadriceps force required to extend the knee during an isokinetic extension cycle of different total knee designs, focusing on the radius of the femoral component (single vs. multiple). METHODS Human knee specimens (n = 12, median patient age 68 (63-70) years) were tested in a kinematic knee-simulating machine untreated and after implantation of 2 types of knee prosthesis systems, one with a single femoral radius design and one with a multiple femoral radius design. During the test cycle, a hydraulic cylinder, which simulated the quadriceps muscle, applied sufficient force to the quadriceps tendon to produce a constant extension moment of 31 Nm. The quadriceps extension force was measured from 120° to full knee extension. RESULTS The shape of the quadriceps force curve was typically sinusoidal before and after TKA, reaching a maximum value of 1,493 N at 110°. With the single femoral radius design, quadriceps force was similar to that of the normal knee: 1,509 N at 110° flexion (p = 0.4). In contrast, the multiple femoral radius design showed an increase in quadriceps extension force relative to the normal knee, with a maximum of 1,721 N at 90° flexion (p = 0.03). INTERPRETATION The single femoral radius design showed lower maximum extension forces than the multiple femoral radius design. In addition, with the single femoral radius design maximum quadriceps force needed to extend a constant extension force shifted to higher degrees of knee flexion, representing a more physiological quadriceps force pattern, which could have a positive effect on knee function after TKA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is Single-Radius Design Better for Quadriceps Recovery in Total Knee Arthroplasty?

PURPOSE Although single-radius (SR) designs have a theoretical advantage in quadriceps recovery following total knee arthroplasty (TKA), there has been a paucity of objective evaluation studies. MATERIALS AND METHODS One hundred and twenty minimally invasive TKAs were prospectively randomized by a single surgeon into 2 groups: SR design TKA group and multi-radius design TKA group. Quadriceps ...

متن کامل

Single radius of curvature implant design enhances patient lower limb power output following total knee arthroplasty

Most knee implants are multi radius in design, incorporating a shifting centre of rotation of the knee as it moves through flexion. Recent advances in kinematic theory however suggest a single axis of flexion / extension is located in the distal femur. A recently launched TKA implant (Triathlon, Stryker US®), is based on this theory, adopting a single radius of curvature femoral component. It i...

متن کامل

Mid-term Results of Single-Radius Cruciate Retaining Total Knee Arthroplasty: Minimum 5 Year Follow-up

PURPOSE The single-radius design of the knee implant was introduced to improve the results of total knee arthroplasty (TKA) by reducing maximum extensor forces, and it also represents more physiologic quadriceps force pattern, which could have a positive effect on knee function after TKA. We studied mid-term results of single-radius designed cruciate retaining (CR) TKA. MATERIALS AND METHODS ...

متن کامل

Does Cruciate-Retaining Total Knee Arthroplasty Show Better Quadriceps Recovery than Posterior-Stabilized Total Knee Arthroplasty? - Objective Measurement with a Dynamometer in 102 Knees

BACKGROUND Cruciate-retaining (CR) prostheses have been considered to produce more physiologic femoral rollback, provide better proprioception, and result in better quadriceps recovery than posterior-stabilized (PS) prostheses after total knee arthroplasty (TKA). However, there are very few studies demonstrating these benefits in an objective manner. We investigated whether CR-TKA could result ...

متن کامل

Anteroposterior Knee Stability During Stair Descent.

This study examined the influence of tibio-femoral conformity on anteroposterior (AP) knee stability during stair descent, particularly with a dished cruciate sacrificing (CS) design. A joint simulator simulated stair descent of cadaveric knees. Tibio-femoral displacement was measured. Knees were tested in intact, ACL-deficient, and TKA with cruciate-retaining (CR), CS and posterior-stabilizing...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 82  شماره 

صفحات  -

تاریخ انتشار 2011