Comparison between Deflection and Vibration Characteristics of Rectangular and Trapezoidal profile Microcantilevers
نویسندگان
چکیده
Arrays of microcantilevers are increasingly being used as physical, biological, and chemical sensors in various applications. To improve the sensitivity of microcantilever sensors, this study analyses and compares the deflection and vibration characteristics of rectangular and trapezoidal profile microcantilevers. Three models of each profile are investigated. The cantilevers are analyzed for maximum deflection, fundamental resonant frequency and maximum stress. The surface stress is modelled as in-plane tensile force applied on the top edge of the microcantilevers. A commercial finite element analysis software ANSYS is used to analyze the designs. Results show paddled trapezoidal profile microcantilevers have better sensitivity.
منابع مشابه
Analysis of Detection Enhancement Using Microcantilevers with Long-Slit-Based Sensors
The present work analyzes theoretically and verifies the advantage of utilizing rectangular microcantilevers with long-slits in microsensing applications. The deflection profile of these microcantilevers is compared with that of typical rectangular microcantilevers under the action of dynamic disturbances. Various force-loading conditions are considered. The theory of linear elasticity for thin...
متن کاملDeflection, Frequency, and Stress Characteristics of Rectangular, Triangular, and Step Profile Microcantilevers for Biosensors
This study presents the deflection, resonant frequency and stress results of rectangular, triangular, and step profile microcantilevers subject to surface stress. These cantilevers can be used as the sensing element in microcantilever biosensors. To increase the overall sensitivity of microcantilever biosensors, both the deflection and the resonant frequency of the cantilever should be increase...
متن کاملBending and Free Vibration Analyses of Rectangular Laminated Composite Plates Resting on Elastic Foundation Using a Refined Shear Deformation Theory
In this paper, a closed form solution for bending and free vibration analyses of simply supported rectangular laminated composite plates is presented. The static and free vibration behavior of symmetric and antisymmetric laminates is investigated using a refined first-order shear deformation theory. The Winkler–Pasternak two-parameter model is employed to express the interaction between the lam...
متن کاملSimplified Aeroelastic Model for Fluid Structure Interaction between Microcantilever Sensors and Fluid Surroundings
Fluid-structural coupling occurs when microcantilever sensors vibrate in a fluid. Due to the complexity of the mechanical characteristics of microcantilevers and lack of high-precision microscopic mechanical testing instruments, effective methods for studying the fluid-structural coupling of microcantilevers are lacking, especially for non-rectangular microcantilevers. Here, we report fluid-str...
متن کاملAnalysis of Deflection Enhancement Using Epsilon Assembly Microcantilevers Based Sensors
The present work analyzes theoretically and verifies the advantage of utilizing ɛ-microcantilever assemblies in microsensing applications. The deflection profile of these innovative ɛ-assembly microcantilevers is compared with that of the rectangular microcantilever and modified triangular microcantlever. Various force-loading conditions are considered. The theorem of linear elasticity for thin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2009