Theoretical and practical requirements for the valid measurement by indicator-dilution of regurgitant flow across incompetent valves.
نویسندگان
چکیده
A theory is presented for the measurement of regurgitant flow across an incompetent valve hy injection of indicator distal to the valve and recording of time concentration curves proximal and distal to the valve. The conditions which must be met for valid measurements are examined and demonstrated by a functioning mechanical model of the heart. The method is valid regardless of the size of the residual volumes or degree of mixing with these volumes if a representative sample of the concentration of indicator in the blood moving across the valve in both directions is obtained.
منابع مشابه
Use of indicator dilution techniques in measuring combined aortic and mitral insufficiency.
• When aortic and mitral valvular insufficiency are present in the same patient, indicator injected into the aortic root regurgitates into the left ventricle and thence into the left atrium. The purpose of this paper is to describe the indicator distribution in such patients and to compare the relationships found with those predicted from a theoretical model of bivalvular insufficiency. Indicat...
متن کاملQuantification of Aortic and Mitral Regurgitation Using Heart Motion Adapted Cine Phase Contrast Flow Measurements
Introduction Chronic aortic and mitral regurgitation place an additional hemodynamic load on the left ventricle (LV). Substantial LV chamber dilation, as assessed with echocardiographic techniques, is commonly used as an indirect marker of volume overload. However, for asymptomatic and minimally symptomatic patients the direct measure of regurgitant volume would be the key parameter for patient...
متن کاملColor Doppler regurgitant characteristics of normal mechanical mitral valve prostheses in vitro.
BACKGROUND To evaluate normal regurgitant characteristics of St. Jude (SJ) and Medtronic-Hall (MH) mitral valves, four sizes (25-31 mm) of each were studied in a pulsatile flow model. METHODS AND RESULTS Regurgitant flow was measured by flowmeter at left ventricular pressures of 80, 130, and 180 mm Hg. Peak regurgitant flow rates ranged from 6.2 to 12.7 cm3/sec in SJ valves and from 7.9 to 17...
متن کاملMeasurement of regional cerebral blood flow using ultrafast computed tomography. Theoretical aspects.
Theoretical and practical limitations have prevented the measurement of regional cerebral blood flow using dynamic x-ray computed tomography. Development of the ultrafast computed tomography scanner has made it possible to overcome the practical limitations and measure changes in contrast concentration in the brain with excellent time and spatial resolution. By applying modifications of indicat...
متن کاملMeasurement of mitral regurgitation in man from simultaneous atrial and arterial dilution curves after ventricular injection.
THE MOST DIRECT APPROACH to measurement of the volume of blood regurgitating across an insufficient mitral valve consists of the injection of indicator into the left ventricle and simultaneous sampling of blood from the left atrium and from the aorta or one of its branches. If mixing is complete in the left ventricle, the distribution of indicator to upstream and downstream collection sites is ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation research
دوره 7 3 شماره
صفحات -
تاریخ انتشار 1959