Infection of Retained Defibrillator Lead Fragment after Heart Transplant

نویسندگان

  • Emanuele Durante-Mangoni
  • Martina Vitrone
  • Irene Mattucci
  • Vincenzo Caprioli
  • Ciro Maiello
چکیده

A 59-year old heart transplant recipient was admitted due to continuous pain in her left axilla. A purulent collection was found at the site of prior defibrillator placement, where a remnant proximal segment of an electric lead was found. Two years before, the patient had had pocket infection treated with revision, but without device extraction. The remnant lead was eventually removed transvenously without complications. This is the first description of infection complicating retention of lead fragments after heart transplant. The role of biofilm and net immune state on the persistence and late recurrence of infection is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Candida glabrata Infection on Retained Implantable Cardioverter Defibrillator Lead in Heart Transplant Patient Requiring Redo Upper Mini-Sternotomy Approach

We present the first documented case of a Candida glabrata infection on the retained lead of a cardiovascular implantable electronic device (CIED) in an immunosuppressed heart transplant recipient. This is the first documented case of a redo upper mini-sternotomy approach for a lead removal and innominate vein reconstruction with bovine patch. The patient is a 55 year-old male with non-ischemic...

متن کامل

Frequency and clinical impact of retained implantable cardioverter defibrillator lead materials in heart transplant recipients

End-stage heart failure patients with implantable cardioverter-defibrillator (ICD) with/without cardiac resynchronization therapy (CRT-D) often require heart transplantation (HTPL) as a last-resort treatment. We aimed to assess the frequency and clinical impact of retained ICD lead materials in HTPL patients. In this retrospective single center study, we examined the clinical records and chest ...

متن کامل

Three-dimensional computed tomography imaging of an implantable cardioverter-defibrillator lead fragment in the left ventricle of a heart transplant followed by successful transarterial extraction with a snare catheter.

We report on a 51-year old heart transplant recipient in whom a pacing lead fragment of his old implantable cardioverter-defibrillator (ICD) had been detected in the left ventricle following successful heart transplantation. The patient was transplanted after 5 weeks on high urgent status. A postoperative routine chest X-ray and a subsequent cardiac three-dimensional (3D) computed tomography sc...

متن کامل

Heart Transplantation After Cardioverter - Defibrillator lmplantation

A case control study was performed to determine whether previous implantable cardioverter-defibrillator(ICD)insertion adversely affects outcome after heart transplantation. Six male heart transplant recipients who had undergone lCD insertion 12 ±5 months before heart transplantation were compared to a cohort ofsix heart transplant recipients who were matched according to age, preoperative statu...

متن کامل

Infections after cardioverter-defibrillator implantation: observations in 335 patients over 10 years.

OBJECTIVE To determine the incidence of infection after implantation of a cardioverter-defibrillator and the management of this complication. SUBJECTS 335 consecutive patients who had a cardioverter-defibrillator implanted between January 1984 and December 1993. MAIN OUTCOME MEASURES Incidence of infection within the first month after implantation (early infection) and after the first month...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017