Evaluation of Force Degradation Pattern of Elastomeric Ligatures and Elastomeric Separators in Active Tieback State.
نویسندگان
چکیده
Background and aims. The purpose of this study was to evaluate initial force and force decay of commercially available elastomeric ligatures and elastomeric separators in active tieback state in a simulated oral environment. Materials and methods. A total of 288 elastomeric ligatures and elastomeric separators from three manufacturers (Dentaurum, RMO, 3M Unitek) were stretched to 100% and 150% of their original inner diameter. Force levels were measured initially and at 3-minute, 24-hour, and 1-, 2-, 3- and 4-week intervals. Data were analyzed by univariate analysis of variance and a post hoc Tukey test. Results. The means of initial forces of elastomeric ligatures and separators from three above-mentioned companies, when stretched to 100% of their inner diameters, were 199, 305 and 284 g, and 330, 416, 330 g; when they were stretched to 150% of their inner diameters the values were 286, 422 and 375 g, and 433, 540 and 504 g, respectively. In active tieback state, 11-18% of the initial force of the specimens was lost within the first 3 minutes and 29-63% of the force decay occurred in the first 24 hours; then force decay rate decreased. 62-81% of the initial force was lost in 4 weeks. Although force decay pattern was identical in all the products, the initial force and force decay of Dentaurum elastomeric products were less than the similar products of other companies (P<0.05). Under the same conditions, the force of elastomeric separators was greater than elastomeric ligatures of the same company. Conclusion. Regarding the force pattern of elastomeric ligatures and separators and optimal force for tooth movement, many of these products can be selected for applying orthodontic forces in active tieback state.
منابع مشابه
Comparing the elastomeric behavior and force degradation pattern between different orthodontic elastomeric chains
Background and Aims: Elastomeric chains are known as a current device with the purpose of dental movement in orthodontic treatments. The aim of this study was to compare the elastomeric behavior and force degradation rate between different elastomeric chains existing in Iran in different time durations. Materials and Methods: 11 different elastomeric chains used in this study were: Class One, ...
متن کاملEvaluation of the effect of different stretching patterns on force decay and tensile properties of elastomeric ligatures
BACKGROUND There have been numerous researches on elastomeric ligatures, but clinical conditions in different stages of treatment are not exactly similar to laboratory conditions. The aim of this in vitro study was to simulate clinical conditions and evaluate the effect of three stretching patterns on the amount of force, tensile strength (TS) and extension to TS of the elastomers during 8 week...
متن کاملSuperficial morphology and mechanical properties of in vivo aged orthodontic ligatures.
INTRODUCTION The degradation of elastic ligatures in the oral environment results in the need of periodic replacement to maintain the optimal force during the orthodontic treatment. The purpose of this study was to perform a clinical prospective randomized study of the degradation of orthodontic elastomeric ligatures in the oral environment by scanning electron microscopy (SEM) and tensile stre...
متن کاملEffect on Mechanical Properties of Orthodontic Elastomeric Ligatures on Immersion in Disinfecting Solutions - an in vitro Study
Background and Objectives: Cold water disinfection can damage the elastomeric material, cross contamination in handling elastomeric ligatures is a serious concern in the orthodontic office. In addition, elastomeric strips with enough ligatures for both arches of a single patient are produced by most manufacturers. Thus, cross -contamination can occur in remaining ligatures if an entire strip is...
متن کاملFrictional resistance in monocrystalline ceramic brackets with conventional and nonconventional elastomeric ligatures
BACKGROUND The objective of this study was to compare the frictional forces generated by three types of monocrystalline ceramic brackets coupled with conventional elastomeric ligatures (CEL) and nonconventional elastomeric ligatures (NCEL) during the alignment of apically displaced teeth at the maxillary arch. METHODS All tests (a total of 480 tests) were carried out in a dry state on a unive...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of dental research, dental clinics, dental prospects
دوره 9 4 شماره
صفحات -
تاریخ انتشار 2015