SU-E-T-16: Statistical Variability and Confidence Intervals for Planar Dose QA Pass Rates.

نویسندگان

  • D Bailey
  • B Nelms
  • L Kumaraswamy
  • K Attwood
  • M Podgorsak
چکیده

PURPOSE The most common metric for comparing measured to calculated dose planes is a pass rate generated using percent difference, distance-to-agreement (DTA), or some combination of the two (e.g. gamma evaluation). The grid of analyzed points often corresponds to a dosimeter array with low areal-density of point detectors. This work examines the statistical uncertainty of planar dose comparison pass rates and proposes methods for establishing confidence intervals for pass rates obtained with low detector-density arrays. METHODS Absolute dose planes were acquired via EPID for twenty intensity-modulated fields of varying complexity. Matching calculated dose planes were created via treatment planning system. Pass rates for each dose plane pair (centered to CAX) were calculated with various %/DTA composite analysis techniques. Software was designed to selectively sample the high-density EPID matrix to simulate many low-density measured grids, each representing a different alignment with respect to CAX. Simulations were repeated (100 positional iterations per field) using grids of varying detector-densities and both random and orthogonal point-detector orientation. For each simulation, pass rates were calculated with various composite analysis techniques. RESULTS Repositioning simulated low-density grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair, independent of whether the detector grid is random or uniform. Distributions can be predicted using a binomial distribution by which a confidence interval (function of sampling density and observed pass rate) is approximated for each pass rate. For example, 95% confidence intervals for IMRT pass rates (2%,2mm) average +/-5.3% and +/-3.8% with 1-detector/cm2 and 2-detector/cm2 grids, respectively. CONCLUSIONS Pass rates for low-density array measurements are not absolute and should be reported with both a full description of calculation method and confidence intervals quantifying their uncertainty. Results extend to 3D detector arrays. The concept of fixed 'action levels' for pass rates must be reexamined for low-density array measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Curtailing patient-specific IMRT QA procedures from 2D dose error distribution

A patient-specific quality assurance (QA) test is conducted to verify the accuracy of dose delivery. It generally consists of three verification processes: the absolute point dose difference, the planar dose differences at each gantry angle, and the planar dose differences by 3D composite irradiation. However, this imposes a substantial workload on medical physicists. The objective of this stud...

متن کامل

SU-E-T-164: Clinical Implementation of ASi EPID Panels for QA of IMRT/VMAT Plans.

PURPOSE To investigate various issues for clinical implementation of aSi EPID panels for IMRT/VMAT QA. METHODS Six linacs are used in our clinic for EPID-based plan QA; two Varian Truebeams, two Varian 2100 series, two Elekta Infiniti series. Multiple corrections must be accounted for in the calibration of each panel for dosimetric use. Varian aSi panels are calibrated with standard dark fiel...

متن کامل

Confidence Intervals for the Power of Two-Sided Student’s t-test

For the power of two-sided hypothesis testing about the mean of a normal population, we derive a 100(1 − alpha)% confidence interval. Then by using a numerical method we will find a shortest confidence interval and consider some special cases.

متن کامل

SU-E-T-170: A Viable Approach to Patient Specific QA for Spine VMAT SRS Using EPID-Based Dosimetry.

PURPOSE VMAT involves multi-parameter modulations, thus presenting multi-dimensional challenges. Here, we present a viable approach to VMAT patient specific QA using EPID-based dosimetry for spine VMAT SRS casesMethods: Our spine VMAT SRS plans consisted of two full arcs and were optimized with 6 MV photons for a Varian Trilogy LINAC. The QA plans were computed by resetting all control points t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 38 11  شماره 

صفحات  -

تاریخ انتشار 2011