Determination of the Degree of Degradation of Frying Rapeseed Oil Using Fourier-Transform Infrared Spectroscopy Combined with Partial Least-Squares Regression

نویسندگان

  • Jie Yu Chen
  • Han Zhang
  • Jinkui Ma
  • Tomohiro Tuchiya
  • Yelian Miao
چکیده

This rapid method for determining the degree of degradation of frying rapeseed oils uses Fourier-transform infrared (FTIR) spectroscopy combined with partial least-squares (PLS) regression. One hundred and fifty-six frying oil samples that degraded to different degrees by frying potatoes were scanned by an FTIR spectrometer using attenuated total reflectance (ATR). PLS regression with full cross validation was used for the prediction of acid value (AV) and total polar compounds (TPC) based on raw, first, and second derivative FTIR spectra (4000-650 cm(-1)). The precise calibration model based on the second derivative FTIR spectra shows that the coefficients of determination for calibration (R (2)) and standard errors of cross validation (SECV) were 0.99 and 0.16 mg KOH/g and 0.98 and 1.17% for AV and TPC, respectively. The accuracy of the calibration model, tested using the validation set, yielded standard errors of prediction (SEP) of 0.16 mg KOH/g and 1.10% for AV and TPC, respectively. Therefore, the degradation of frying oils can be accurately measured using FTIR spectroscopy combined with PLS regression.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of carbonyl value of frying oil by fourier transform infrared spectroscopy.

A rapid method for determining the carbonyl value of frying oils has been developed using Fourier-transform infrared (FTIR) spectroscopy and chemometrics. One hundred and fifty-six frying oils with different carbonyl values were collected from an actual potato frying process. FTIR spectra in the range of 4000-650 cm(-1) were scanned with a FTIR spectroscopy apparatus using the attenuated total ...

متن کامل

Determination of Protein and Moisture in Fishmeal by Near-Infrared Reflectance Spectroscopy and Multivariate Regression Based on Partial Least Squares

The potential of Near Infrared Reflectance Spectroscopy (NIRS) as a fast method to predict the Crude Protein (CP) and Moisture (M) content in fishmeal by scanning spectra between 1000 and 2500 nm using multivariate regression technique based on Partial Least Squares (PLS) was evaluated. The coefficient of determination in calibration (R2C) and Standard Error of Calibra...

متن کامل

Predicting of Effective Dose as Biomarker for Cytotoxicity Using Partial Least Square-Fourier Transform Infrared Spectroscopy (PLS_FTIR)

Toxicity bioassays are important tools to determine biological effects of chemical agents on species. The questions remained on, what effects have been imposed on each of the different molecular site of cells by chemical exposure and how to find a pattern for chemical toxicity. To address the questions, HepG2 cell lines were exposed to the different concentrations of cisplatin for 24 hours to r...

متن کامل

Predicting of Effective Dose as Biomarker for Cytotoxicity Using Partial Least Square-Fourier Transform Infrared Spectroscopy (PLS_FTIR)

Toxicity bioassays are important tools to determine biological effects of chemical agents on species. The questions remained on, what effects have been imposed on each of the different molecular site of cells by chemical exposure and how to find a pattern for chemical toxicity. To address the questions, HepG2 cell lines were exposed to the different concentrations of cisplatin for 24 hours to r...

متن کامل

Determination of polar components in frying oils by Fourier-transform near-infrared spectroscopy.

A rapid and convenient method was developed to determine the polar components (PC) of frying oil by Fourier-transform near-infrared (FTNIR) spectroscopy. One hundred twenty six oil samples were used to PC determination by column chromatography and FTNIR spectroscopy combined with partial least-square (PLS) calibration. The optimal PLS calibration was obtained after the Savitzky-Golay smoothing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015