Characterization of dysgonic, heterotrophic bacteria from drinking water.

نویسنده

  • D F Spino
چکیده

Only a small percentage of the heterotrophic bacteria encountered in water distribution systems are identifiable, because of these organisms fail to grow on the conventional media used for biochemical characterization. Organisms that would not subculture from the same standard plate count agar used for initial isolation were successfully subcultured on a low-nutrient medium, R3A. These cultures were then inoculated to a modified O/F base medium containing specific substrates. This, combined with a lower incubation temperature (30 degrees C), increased the enzymatic activity of many of the organisms. These reactions established a groundwork for tentative taxonomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heterotrophic Bacteria Count Index in Drinking Water and Possibility of Biofilm Formation in Household Drinking Water Treatment Devices in Sari, Iran

 Background and purpose: Household drinking water treatment devices are becoming commonplace to improve the quality of drinking water, remove odor, taste, turbidity and color, pathogenic organisms, toxic chemicals, organic matter, and carcinogenic pollutants. This study aimed at investigating the Heterotrophic plate count (HPC) in drinking water and possibility of biofilm formation in household...

متن کامل

Effect of pH, Chlorine Residual and Turbidity on the Microbial Bio Indicators of Drinking Water Network

Abstract Background and objective: Bioindicators of drinking water are always influenced by physical and chemical factors such as turbidity and chlorine.  Considering the assessment of drinking water quality is based on residual chlorine, E.coli, heterotrophic bacteria and turbidity.  We aimed to evaluate the effect of pH, chlorine residual and turbidity on the microbial ...

متن کامل

باکتری‌های هتروتروف در آب آشامیدنی شهر تبریز

Background and Aim: Recently the use of heterotrophic plate count (HPC) has received much attention as a supplementary indicator of the MPN test in water quality control. The US Environmental Protection Agency (USEPA) has declared 500 cfu/mL as the maximum acceptable level for heterotrophic bacteria in distribution networks. Currently the HPC determination is not among the routine control items...

متن کامل

A survey of heterotrophic bacteria and coliforms in the water of old and new distribution networks

Controlling the microbiological quality of water is important for its uses. Microbiological requirements of drinking water ensure the absence of coliforms, but may indicate the potential presence of other potentially pathogenic microorganisms and viruses of fecal origin. A total of 36 water samples, representing the drinking water of the whole city of Aradan, Semnan, Iran, were randomly collect...

متن کامل

ارزیابی اثر آب سرد کن های متداول بر روی کیفیت آب آشامیدنی

Backgrounds and Objectives: Drinking water quality after treatment and before reaching  the consumer could be affected by distribution pipes, service lines and Home devices. The structure of water coolers, a home device that are widely used in warm months of the year, could potentially affect the quality of drinking water. The aim of this study was to assess the microbial and chemical quality o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 50 5  شماره 

صفحات  -

تاریخ انتشار 1985