Improved separation of fetal hemoglobin by mini-column chromatography.

نویسندگان

  • L G Morin
  • E G Barton
چکیده

We present chromatographic conditions for separating and measuring fetal hemoglobin on a 5-cm column of Sephadex CM-50. A distinct fetal band is evident, even when present at less than 1% of total hemoglobin. Precision (CV) of better than 5% is achievable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Postnatal Fetal and Adult Hemoglobin Synthesis in D Trisomy Syndrome

Studies were carried out during the neonatal period in three infants with D1 trisomy syndrome to measure the proportion of fetal and adult hemoglobin being synthesized. These values were compared on the one hand to those previously reported from samples obtained from cord blood of normal newborn infants ranging from 25 to 43 wk gestation, and on the other hand to those values determined in crit...

متن کامل

Postnatal fetal and adult hemoglobin synthesis in D 1 trisomy syndrome.

Studies were carried out during the neonatal period in three infants with D1 trisomy syndrome to measure the proportion of fetal and adult hemoglobin being synthesized. These values were compared on the one hand to those previously reported from samples obtained from cord blood of normal newborn infants ranging from 25 to 43 wk gestation, and on the other hand to those values determined in crit...

متن کامل

Postnatal Fetal and Adult Hemoglobin Synthesis in Preterm Infants Whose Birth

A B S T R A C T To determine if environmental factors could effect the switchover from fetal hemoglobin (HbF) to adult hemoglobin (HbA) synthesis, studies were carried out on blood samples from eight infants born at <1,000 g, when they had reached their postconceptional age corresponding to term. All of these infants required prolonged intensive care, multiple blood transfusions, and two requir...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

The Comparison of Silica Gel-Alumina Sorbents for Separation of PAHs and PCBs

The aim of this research is to develop a silica gel and alumina column chromatography for separation of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) into two groups. This is achieved by optimizing the cut-off volume of eluting solvent and weight ratio of silica gel and alumina. In this process mixture of PAHs and PCBs divide in two groups and simultaneously o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 33 2 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1987