Using high-resolution MR imaging at 7T to evaluate the anatomy of the midbrain dopaminergic system.

نویسندگان

  • M Eapen
  • D H Zald
  • J C Gatenby
  • Z Ding
  • J C Gore
چکیده

BACKGROUND AND PURPOSE Dysfunction of DA neurotransmission from the SN and VTA has been implicated in neuropsychiatric diseases, including Parkinson disease and schizophrenia. Unfortunately, these midbrain DA structures are difficult to define on clinical MR imaging. To more precisely evaluate the anatomic architecture of the DA midbrain, we scanned healthy participants with a 7T MR imaging system. Here we contrast the performance of high-resolution T2- and T2*-weighted GRASE and FFE MR imaging scans at 7T. MATERIALS AND METHODS Ten healthy participants were scanned by using GRASE and FFE sequences. CNRs were calculated among the SN, VTA, and RN, and their volumes were estimated by using a segmentation algorithm. RESULTS Both GRASE and FFE scans revealed visible contrast between midbrain DA regions. The GRASE scan showed higher CNRs compared with the FFE scan. The T2* contrast of the FFE scan further delineated substructures and microvasculature within the midbrain SN and RN. Segmentation and volume estimation of the midbrain SN, RN, and VTA showed individual differences in the size and volume of these structures across participants. CONCLUSIONS Both GRASE and FFE provide sufficient CNR to evaluate the anatomy of the midbrain DA system. The FFE in particular reveals vascular details and substructure information within the midbrain regions that could be useful for examining structural changes in midbrain pathologies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

STRUCTURAL AND FUNCTIONAL EVALUATION OF THE HUMAN MIDBRAIN DOPAMINERGIC SYSTEM USING HIGH RESOLUTION MRI AT 7 T By

A number of optimization steps needed to be implemented in order to develop an MR imaging protocol that could accurately capture the anatomy of the midbrain dopaminergic (DA) ventral tegmental area (VTA) and substantia nigra (SN). The current study explored imaging parameters that included MR sequence selection, slice orientation and positioning, spatial voxel resolution, TE (Time to Echo) and ...

متن کامل

Cinnamaldehyde attenuates dopaminergic neuronal loss in substantia nigra and induces midbrain catalase activity in a mouse model of Parkinson’s disease

Background and Objective: Parkinson's disease (PD) is the second most common neurodegenerative disease after Alzheimer's disease that affects 3% of the population. PD involves a progressive degeneration of dopaminergic neurons in the substantia nigra pars compacta (SNc) and subsequent loss of dopamine. Dopamine depletion leads to movement dysfunction and is accompanied with tremor, rigid muscle...

متن کامل

Visualization of human inner ear anatomy with high-resolution MR imaging at 7T.

W e read with interest the article by van der Jagt et al 1 describing the visualization of the scala media of the cochlea in living human subjects by non-contrast-enhanced T2-weighted imaging at 7T. For recognition of the scala media with this technique , visualization of the Reissner membrane is necessary. The Reissner membrane is very thin, 4 –12 ␮m. 2 Visualization of this thin membrane in a...

متن کامل

Ultra high resolution venography using T2* weighted imaging at 7T MRI

Throughout the last two decades, MRI has been ameliorated by a dramatic increase in the field strength; from 0.015 to 7 Tesla (T) MR systems. Ultrahigh-field MR system (beyond 3T) has great potential to produce newly improved imaging capabilities for both clinical diagnosis and basic science research. The primary purpose of venography was the description of cerebral veins, but it has also been ...

متن کامل

Investigation of the Spatial Resolution of MR-Based Polymer Gel Dosimetry versus Film Densitometry using Dose Modulation Transfer Function

Introduction: The conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. Although the polymer gel dosimetry method based on magnetic resonance imaging (MRI) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 32 4  شماره 

صفحات  -

تاریخ انتشار 2011