Operational Note Samplers for Evaluation and Quantification of Ultra-low Volume Space Sprays
نویسندگان
چکیده
A field study was conducted to explore the suitability of 5 pesticide deposition samplers for airborne spray and ground deposits from ultra-low-volume (ULV) space sprays. Samplers included horizontally stretched stationary cotton ribbons at 2 heights, rotating ribbon, rotating Teflon slides, and filter paper. Slides were also used for droplet-size analysis. A set of 7 samplers of each type was placed at 1, 7, 15, 25, 40, 65, and 90 m from the spray line along the spray swath. Water and BVA13 oil with fluorescent dyes as tracers were sprayed with the use of a truck-mounted ULV sprayer at dusk and dawn. Results suggest that the horizontal and rotating cotton ribbons are best for quantification of airborne spray and filter paper is best for ground deposition collection. The rotating slide samplers only detected the BVA13 oil-based sprays.
منابع مشابه
Samplers for evaluation and quantification of ultra-low volume space sprays.
A field study was conducted to explore the suitability of 5 pesticide deposition samplers for airborne spray and ground deposits from ultra-low-volume (ULV) space sprays. Samplers included horizontally stretched stationary cotton ribbons at 2 heights, rotating ribbon, rotating Teflon slides, and filter paper. Slides were also used for droplet-size analysis. A set of 7 samplers of each type was ...
متن کاملUltra-low-volume space sprays in mosquito control: a critical review.
The availability of tools to control mosquito (Diptera:Culicidae) vectors that transmit disease is often limited by a variety of economic, environmental and social issues. In emergency conditions (epidemics, hurricanes, floods etc.), the application of pesticides as space sprays (either by ground or air) is the common method of choice in order to rapidly limit adult local mosquito production in...
متن کاملOperational Note Temporal and Storage Effects on Ultra-low Volume Droplets of Insecticides Collected on Teflonh-coated Slides
Use of microscope slides is the most commonly used method to field-assess the droplet spectrum of ultra-low volume (ULV) sprays. Due to absence of analysis facilities during military deployments, slides must be stored and shipped, and the impact of delays in processing and storage conditions on droplets is unknown. This study was designed to evaluate the effect of storage temperatures and durat...
متن کاملAn Ultra High CMRR Low Voltage Low Power Fully Differential Current Operational Amplifier (COA)
this paper presents a novel fully differential (FD) ultra high common mode rejection ratio (CMRR) current operational amplifier (COA) with very low input impedance. Its FD structure that attenuates common mode signals over all stages grants ultra high CMRR and power supply rejection ratio (PSRR) that makes it suitable for mixed mode and accurate applications. Its performance is verified by HSPI...
متن کاملSouthwestern Entomologist Mar. 2003 Longevity of Ultra-low-volume Sprays of Fipronil and Malathion on Cotton in Mexico
In 1996, fipronil and malathion residues were evaluated after four ultra-low-volume (ULV) spray applications in northeastern Tarnaulipas, Mexico. Sprays were applied at 0.88 L/ha. Fipronil was applied at 28 and 56 g A.I./ha and malathion at 840 g A.I./ha. Four applications were made beginning 23 May at four, five and six day intervals. Leaf surface residues of malathion accumulated with each ap...
متن کامل