Particle size of beclomethasone dipropionate produced by two nebulisers and two spacing devices.

نویسنده

  • C O'Callaghan
چکیده

An impactor method was used to assess the amount of beclomethasone dipropionate in particles less than 5 microns produced by two nebulisers (Pari Inhalierboy, Medix Traveller compressor with cirrhus nebuliser chamber) and two spacer devices (Volumatic and Nebuhaler). After nebulisation of 3 ml (150 micrograms) beclomethasone dipropionate the amount of drug in particles less than 5 microns was 16 micrograms (GSD 1.1) with the Pari Inhalierboy, and 27 micrograms (1.4) with the Medix Traveller with cirrhus nebuliser. This was less than the amount in particles less than 5 microns after three metered dose inhaler actuations (150 micrograms) from the Nebuhaler (58.2 (1) micrograms) or the Volumatic spacer (46.5 (1) micrograms). The greater amount of beclomethasone dipropionate in small particles with administration from a metered dose inhaler with a spacer device means that considerably more drug is likely to reach the airways than when the same dose is given by the two nebulisers studied.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of HFA- and CFC-beclomethasone dipropionate on the bronchial response to methacholine (MCh) in mild asthma.

Metered inhalers using chlorofluorocarbon (CFC) propellents have been gradually replaced by new devices that use hydrofluoroalkanes (HFAs) as their propellents, which are less harmful to the environment. This reformulation led to a substantial improvement of the previous technologies applied to inhalation devices and of the physical characteristics of drugs delivered. In particular, inhaled cor...

متن کامل

Effect of a volumatic spacer and mouth rinsing on systemic absorption of inhaled corticosteroids from a metered dose inhaler and dry powder inhaler.

BACKGROUND High doses of inhaled corticosteroids are absorbed systemically and may cause long term side effects. As rinsing the mouth out after use and inhaling through a spacing device may reduce systemic absorption this has been further investigated. METHODS Three crossover studies were carried out to assess the effect of budesonide given by dry powder inhaler (Turbuhaler) with and without ...

متن کامل

Differences in aerodynamic particle size distributions of innovator and generic beclomethasone dipropionate aerosols used with and without a large volume spacer.

BACKGROUND The equivalence of generic beclomethasone dipropionate (BDP) formulations with their innovator counterpart must be demonstrated if generic formulations are to be used. This study has examined the aerodynamic particle size distributions of both innovator and generic formulations of BDP and the effect of a large volume spacer (Volumatic) on these distributions. METHODS Aerosol clouds...

متن کامل

Improved airway targeting with the CFC-free HFA-beclomethasone metered-dose inhaler compared with CFC-beclomethasone.

Hydrofluoroalkane-134a (HFA) beclomethasone dipropionate (BDP) was formulated in a metered-dose inhaler (MDI) to deliver a particle size of 1.1 microm compared with 35 microns for currently marketed chlorofluorocarbon (CFC)-BDP products. Two phase I single-dose human deposition studies were conducted using technetium 99m-radiolabelled BDP in a press-and-breathe actuator without an add-on spacer...

متن کامل

Systemic activity of inhaled and swallowed beclomethasone dipropionate and the effect of different inhaler devices.

Inhaled glucocorticoids such as beclomethasone dipropionate, which are used in the treatment of asthma, may be associated with systemic adverse effects. To determine whether any systemic absorption following the inhalation of beclomethasone was a result of drug being absorbed from the lung (inhaled fraction) or the gastrointestinal tract (swallowed fraction), we studied normal subjects after th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 45 2  شماره 

صفحات  -

تاریخ انتشار 1990