Performance of plantar pressure measurement devices (PMDs): update on consensus activities.

نویسنده

  • Claudia Giacomozzi
چکیده

A worldwide scientific discussion has been started in 2010 on the need for standardisation, assessment, and delivery of recommendations in the field of plantar pressure distribution measurement at different levels: hardware performance, measuring protocols, data processing, parameters and indicators in diagnosis and therapy. The Italian National Institute of Health (Istituto Superiore di Sanità, ISS) has been conducting for years a scientific project and several activities aimed to design, validate and implement dedicated testing methods and recommendations in the field of pressure measurement devices (PMDs). The present commentary contains a summary of the activities conducted up to now and some future steps which are going to be done at an international level.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

International scientific consensus on medical plantar pressure measurement devices: technical requirements and performance.

BACKGROUND Since 2006, the Italian National Institute of Health (ISS) has been conducting independent scientific activities to standardize the technical assessment of plantar pressure measurement devices (PMDs). MATERIAL AND METHODS On the basis of the ISS results, in 2010 the Pedobarographic Group of the International Foot and Ankle Biomechanics community (i-FAB-PG) promoted a Consensus acti...

متن کامل

Hardware performance assessment recommendations and tools for baropodometric sensor systems.

Accurate plantar pressure measurements are mandatory in both clinical and research contexts. Differences in accuracy, precision, reliability of pressure measurement devices (PMDs) prevented so far the onset of standardization processes and of reliable reference datasets. The Italian National Institute of Health (ISS) approved and conducted a scientific project aimed to design, validate and impl...

متن کامل

Appropriateness of plantar pressure measurement devices: a comparative technical assessment.

Accurate plantar pressure measurements are mandatory in both clinical and research contexts. Differences in accuracy, precision and reliability of the available devices have prevented so far the onset of standardization processes or the definition of reliable reference datasets. In order to comparatively assess the appropriateness of the most used pressure measurement devices (PMD) on-the-marke...

متن کامل

Pressure measurement devices: from technical assessment to clinical performance

Materials and methods Three commercial PMDs were first assessed and then compared during barefoot walking: PMDa and PMDb resistive technology, 1sens/cm – were assessed onsite, while PMDc – capacitive technology, 4sens/cm was tested on-the-bench and on-site [1]. The PMDs were aligned on the floor to capture successive at-regimen steps of the left foot of one trained volunteer; 10 complete steps ...

متن کامل

تأثیر انواع درمانهای ارتزی بر عملکرد بیماران دیابتی در ایستادن و راه رفتن: مروری بر مقالات

Purpose: Today considering the high prevalence of diabetes and its associated pressure ulcers, also irreparable consequences such as amputation and death, the use of orthotic devices is increasing. A variety of devices have designed to prevent ulcers in the patients’ feet, however other aspects of the treatment, especially the performance of these patients in standing and walking, which a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annali dell'Istituto superiore di sanita

دوره 46 4  شماره 

صفحات  -

تاریخ انتشار 2010