Doppler Radar Architectures and Signal Processing for Heart Rate Extraction

نویسندگان

  • Olga Boric-Lubecke
  • Victor M. Lubecke
  • Isar Mostafanezhad
  • Byung-Kwon Park
  • Wansuree Massagram
  • Branka Jokanovic
چکیده

In this paper heartbeat interval extraction methods using Doppler radar are reviewed. While single channel CW radar offers simple architecture and signal processing, this method is very sensitive to subject position. Quadrature radio architecture is used to overcome this limitation. The use of linear and non-linear demodulation methods was explored for heartbeat interval extraction, and it was demonstrated that heart rate variability analysis is feasible using quadrature Doppler radar.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptation of Rejection Algorithms for a Radar Clutter

In this paper, the algorithms for adaptive rejection of a radar clutter are synthesized for the case of a priori unknown spectral-correlation characteristics at wobbulation of a repetition period of the radar signal. The synthesis of algorithms for the non-recursive adaptive rejection filter (ARF) of a given order is reduced to determination of the vector of weighting coefficients, which realiz...

متن کامل

روشی جدید در بازشناسایی خودکار اهداف متحرک زمینی با استفاده از رادارهای مراقبت زمینی پالس داپلر

A new automatic target recognition algorithm to recognize and distinguish three classes of targets: personnel, wheeled vehicles and animals, is proposed using a low-resolution ground surveillance pulse Doppler radar. The Chirplet transformation, a time frequency signal processing technique, is implemented in this paper. The parameterized RADAR signal is then analyzed by the Zernike Moments (ZM)...

متن کامل

UWB Mixer improvement with Regulated Voltage Source

This paper presents a design of an UWB downconversion integrated CMOS resistive ring mixer with Linear Voltage Regulator (LVR), to supply required biasing voltages for the mixer section. The designed mixer circuit has been optimized for using in heart rate extraction system with microwave Doppler radar at 2.4GHz frequency. This mixer needs 2 DC bias voltages equal to 0.5 and 1 volts for its bes...

متن کامل

Short-Range Noncontact Sensors for Healthcare and Other Emerging Applications: A Review

Short-range noncontact sensors are capable of remotely detecting the precise movements of the subjects or wirelessly estimating the distance from the sensor to the subject. They find wide applications in our day lives such as noncontact vital sign detection of heart beat and respiration, sleep monitoring, occupancy sensing, and gesture sensing. In recent years, short-range noncontact sensors ar...

متن کامل

Efficiency of Target Location Scenarios in the Multi-Transmitter Multi-Receiver Passive Radar

Multi-transmitter multi-receiver passive radar, which locates target in the surveillance area by the reflected signals of the available opportunistic transmitter from the target, is of interest in many applications. In this paper, we investigate different signal processing scenarios in multi-transmitter multi-receiver passive radar. These scenarios include decentralized processing of reference ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010