Pacemaker therapy: the newborn and the nonagenarian.

نویسنده

  • Carsten W Israel
چکیده

The average age of patients with an indication for pacing is 75 years at the time of implantation. However, permanent pacemaker therapy can be necessary at all ages, from newborn to the nonagenarian. Particularly in these age groups, age matters: in small children, there are technical and anatomical considerations that render pacemaker implantation difficult; in very old patients, their relatives, in particular, but also physicians may have concerns about pacemaker implantation that is perceived as too invasive for such an old patient with significant comorbidity. Two publications in this issue of the journal address pacemaker therapy in these two age groups. Pacemaker therapy in children faces several challenges. Transvenous implantation may not be feasible due to lack of venous access to cardiac cavities, or may be difficult due to the small venous diameter that either prevents lead introduction or—if the lead can be introduced—obliterates soon after implantation. Lead dysfunction (lead fracture, exit block, and sensing failure) during growth can occur despite formation of loops of the lead at the time of implant. Therefore, epicardial pacing remains the preferred mode of implantation in small children. As an advantage, the epicardial approach allows dual-chamber pacing earlier than transvenous implantation and left ventricular pacing to prevent adverse haemodynamic long-term consequences of right ventricular pacing. Even though pacing is increasingly applied in paediatric patients, only few long-term data are available on the performance of modern epicardial pacemaker systems. However, these data are necessary to balance advantages and disadvantages of permanent pacing in children in indications outside immediately vital indications. Studies using newer implantable materials and operation techniques have shown improvements in system longevity and long-term function, in particular, lead function has been improved in recent years (Table 1), –11 yearning a 5-year epicardial lead survival of .90% as shown in a study by Kubuš et al. Pacing performance has been improved by the addition of steroids to the lead tip which reduced the risk of exit block by 80%. In this retrospective analysis, the bipolar lead model Medtronic 4968 demonstrated chronic lead integrity similar to the unipolar lead model Medtronic 4965. Thus, advantages of bipolar sensing in epicardial leads come at no cost in terms of lead longevity. Also, the resistance of the lead body and insulation material of epicardial leads has been improved. Lead fractures accounted for only 31% of epicardial lead failures in a recent study, whereas pacing (54%) and sensing problems (14%), most likely due to exaggerated scar formation at the epicardial lead tip, played a more dominant role. In addition to lead improvements with lower chronic pacing thresholds, algorithms such as automatic capture control features prolong battery life significantly. Epicardial pacing with new bipolar leads, which are more resistant to lead fracture and insulation failure and are fitted with steroids at the lead tip, facilitate pacing in small children. With the addition of batteries with extended service duration and automatic algorithms that minimize energy consumption, modern systems can be expected to last much longer than earlier devices, thus reducing the need for battery exchange or lead revision, as shown in the study by Kubuš et al. The possibility to pace the left ventricle and prevent the deleterious effects of chronic right ventricular pacing represents another potential improvement of paediatric pacing therapy. At the other end of the age spectrum, it is a topic of daily discussion in clinical practice—with relatives and patients themselves—if pacing therapy should be applied at an age .85 or 90 years. Arguments used against applying pacing in octogenarians and nonagenarians, particularly in non-life-threatening indications such as sinus node disease, atrial fibrillation with a slow ventricular response, or intermittent high-degree atrioventricular block, include sometimes obvious frailty of the patient, the risk of

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complete Congenital Heart Block in a Neonatal Lupus Erythematosus Associated with Pulmonary Involvement without Pacemaker Implantation: A Case Report

Background: Neonatal lupus erythematosus is an uncommon disease. Congenital complete heart block (CCHB) usually happens in neonates with maternal systemic lupus erythematosus. The most prevalent presentation of CCHBis bradycardiathatcanbediagnosed through an electrocardiogram. Case report: Here in, we present the case of a full-term male neonate with gestational age of 37 weeks and birth weigh...

متن کامل

The influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method

  In radiation therapy with high-energy photon beams (E > 10 MV) neutrons are generated mainly in LINACs head thorough (γ,n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the AAPMTG-34 report, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in the functioning of the pac...

متن کامل

The influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method

Introduction: In radiation therapy with high-energy photon beams (E > 7 MeV) neutrons are generated mainly in LINACs head thorough (γ, n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the protocol TG-34, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in...

متن کامل

Pacemaker lead endocarditis with hiccups (Kalayci)

Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...

متن کامل

Pacemaker Twiddler's Syndrome

A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 2012