BACKGROUND Previous reports have suggested the occurrence of cardiac conduction disorders and permanent pacemaker (PPM) requirement after transcatheter aortic valve implantation (TAVI). Based on a single-center experience, we aim to assess the incidence of postprocedural conduction disorders, need for PPM, and its determinants after TAVI with a self-expanding bioprosthesis. METHODS From August 2007 to October 2009, 32 consecutive patients underwent TAVI with the Medtronic CoreValve (MCV) System (Medtronic Inc., Minneapolis, MN, USA). Three patients paced at baseline and two cases of procedure-related mortality were excluded. We analyzed the 12-lead electrocardiogram at baseline, immediately after procedure and at discharge. Requirements for PPM were documented and potential clinical, electrophysiological, echocardiographic, and procedural predictors of PPM requirement were studied. RESULTS After TAVI, eight patients (29.6%) required PPM implantation due to high-grade atrioventricular (AV) block. The prevalence of left bundle branch block increased from 13.8% to 57.7% directly after implantation (P = 0.001). Need for PPM was correlated to the depth of prosthesis implantation (r = 0.590; P = 0.001). At a cutoff point of 10.1 mm, the likelihood of pacemaker could be predicted with 87.5% sensitivity and 74% specificity and a receiver operator characteristic curve area of 0.86 ± 0.07 (P = 0.003). Of the seven patients with preexisting right bundle branch block (RBBB), four (57.1%) required PPM implantation after TAVI. CONCLUSIONS High-grade AV block requiring PPM implantation is a common complication following TAVI and could be predicted by a deeper implantation of the prosthesis. Patients with preexisting RBBB also seem to be at risk for the development of high-grade AV block and subsequent pacemaker implantation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors predicting and having an impact on the need for a permanent pacemaker after CoreValve prosthesis implantation using the new Accutrak delivery catheter system.

OBJECTIVES The purpose of this study was to evaluate the need for a permanent pacemaker after transcatheter aortic valve implantation with the CoreValve prosthesis (Medtronic, Inc., Minneapolis, Minnesota) using the new Accutrak delivery system (Medtronic, Inc.). BACKGROUND The need for a permanent pacemaker is a recognized complication after transcatheter aortic valve implantation with the C...

متن کامل

Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery.

OBJECTIVES This study sought to evaluate the safety and efficacy of the CoreValve transcatheter heart valve (THV) for the treatment of severe aortic stenosis in patients at extreme risk for surgery. BACKGROUND Untreated severe aortic stenosis is a progressive disease with a poor prognosis. Transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis is a potentially effec...

متن کامل

Preliminary feasibility and hemodynamic performance of a newly-developed self-expanding bioprosthesis and 16-F delivery system in transcatheter aortic valve implantation in sheep

We sought to evaluate the feasibility and hemodynamic performance of a new self-expanding bioprosthesis and 16-F delivery system in sheep. A 23-mm new self-expanding aortic bioprosthesis was implanted in sheep (n = 10) with a 16-F catheter via the right common carotid artery. Each sheep underwent angiography and coronary angiography before intervention, immediately and 1 h after stent implantat...

متن کامل

Transcatheter bioprosthesis implantation for the treatment of aortic stenosis: three-year experience.

BACKGROUND Transcatheter aortic bioprosthesis implantation is a new treatment modality for patients with aortic stenosis who are inoperable or at high surgical risk. OBJECTIVE To report the three-year experience with transcatheter CoreValve® bioprosthesis implantation. METHODS From January 2008 to January 2011, 35 patients with aortic stenosis (33) or aortic valve bioprosthesis dysfunction ...

متن کامل

Intrinsic Atrioventricular Node Conduction Recovery After Transcatheter Aortic Valve Implantation and the Permanent Pacemaker Implantation Enigma

The prevalence of degenerative valvular diseases such as aortic stenosis has continued to rise due to an increase in the aging population globally [1, 2]. Transcatheter aortic valve implantation (TAVI) has emerged to the forefront of severe aortic stenosis treatment, starting with high-risk surgical patients [1, 2]. The minimally invasive approach of TAVI, as established from the promising resu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 33 11  شماره 

صفحات  -