Improved immunoturbidimetric method for rheumatoid factor testing.
نویسندگان
چکیده
The performance of two immunoturbidimetric modifications for rheumatoid factor (RF) testing, which differ with respect to the means of complement inactivation (heat treatment and inactivation with polyvinyl sulphonate), were compared in serum samples from 87 patients with rheumatoid arthritis (RA) and from 403 healthy subjects. IgM-rheumatoid factor titres were also measured with an enzyme linked immunosorbent assay (ELISA). Both immunoturbidimetric tests gave positive reactions (rheumatoid factor > or = 20 IU/ml) in 74 out of the 87 (85%) RA sera. In cases with high RF concentrations the results after chemical inactivation tended to be slightly higher compared with heat inactivation. In healthy subjects rheumatoid factor was detected in 19/403 (4.7%) sera using heat inactivation and in 22/403 (5.5%) sera with chemical inactivation of complement. Interrun coefficient of variation in the chemical inactivation assay was 4.4%; with the heat inactivation method it was 8.1%. In the ELISA, a marginally better correlation was noted in the results obtained using chemical inactivation. Inactivation of complement by means of polyvinyl sulphonate offers the advantage of easier test performance and better reproducibility, and the results may reflect more accurately true rheumatoid factor concentrations.
منابع مشابه
Evaluation of a quantitative immunoturbidimetric assay for rheumatoid factors.
A quantitative immunoturbidimetric assay for rheumatoid factors (RF) is described, based on the immunoprecipitation between aggregated human IgG and rheumatoid factors in serum. The resulting turbidity is measured photometrically at 340 nm. The method is standardized against the WHO international reference preparation and the results are expressed in international units per milliliter (int. uni...
متن کاملImmunoturbidimetric assay for rheumatoid factor using an enzyme
receiving full dose heparin (A kaolin clotting time; 56, 29, and 19 seconds) and four had been considered to have equivocal lupus inhibitor tests. On testing of subsequent samples from three of the equivocal patients, one with a A kaolin clotting time of 29 seconds was found to have a definite lupus inhibitor while the two others (19 and 14 seconds) were negative. The A kaolin clotting time in ...
متن کاملImmunoturbidimetric assay for rheumatoid factor using an enzyme immunoassay microplate reader.
receiving full dose heparin (A kaolin clotting time; 56, 29, and 19 seconds) and four had been considered to have equivocal lupus inhibitor tests. On testing of subsequent samples from three of the equivocal patients, one with a A kaolin clotting time of 29 seconds was found to have a definite lupus inhibitor while the two others (19 and 14 seconds) were negative. The A kaolin clotting time in ...
متن کاملCOMPARISON OF CATION EXCHAGE HPLC AND IMMUNOTURBIDIMETRIC METHOD FOR DETERMINATION OF HbA1c
Objective: The objective of this study was to compare and correlate the analytical performance of D10 Hemoglobin Testing System based on Cation Exchange HPLC and Roche Hitachi 902 Immunoturbidimetric method. Subjects and Methods: A total of 110 patients of Type 2 Diabetes Mellitus were included in the study. HbA1c was determined using D-10 Hemoglobin Testing system and Roche Hitachi 902 Analyze...
متن کاملPotency of Enzymes from Renal Tubules as Biotracers in Rheumatoid Arthritis Patients Treat With Most Used Antirheumatic Drugs
Aim: To estimate the effect of initial therapy with Paracetamol and Ketoprofen on glomerular and tubular integrity in patients with Rheumatoid arthritis (RA), to quantify the toxicity of these drugs through measurements of the enzyme excretion that correlates with the damage degree on the tubular epithelium. Microalbuminuria is used as a marker for glomerular damage, and the urinary excretion o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 46 11 شماره
صفحات -
تاریخ انتشار 1993