Practical one-dimensional measurements of age-related brain atrophy are validated by 3-dimensional values and clinical outcomes: a retrospective study
نویسندگان
چکیده
BACKGROUND Age-related brain atrophy has been represented by simple 1-dimensional (1-D) measurements on computed tomography (CT) for several decades and, more recently, with 3-dimensional (3-D) analysis, using brain volume (BV) and cerebrospinal fluid volume (CSFV). We aimed to show that simple 1-D measurements would be associated with 3-D values of age-related atrophy and that they would be related to post-traumatic intracranial hemorrhage (ICH). METHODS Patients ≥60 years with head trauma were classified with central atrophy (lateral ventricular body width >30 mm) and/or cortical atrophy (sulcus width ≥2.5 mm). Composite atrophy was the presence of central or cortical atrophy. BV and CSFV were computed using a Siemens Syngo workstation (VE60A). RESULTS Of 177 patients, traits were age 78.3 ± 10, ICH 32.2%, central atrophy 39.5%, cortical atrophy 31.1%, composite atrophy 49.2%, BV 1,156 ± 198 mL, and CSFV 102.5 ± 63 mL. CSFV was greater with central atrophy (134.4 mL), than without (81.7 mL, p < 0.001). BV was lower with cortical atrophy (1,034 mL), than without (1,211 mL; p < 0.001). BV was lower with composite atrophy (1,103 mL), than without (1,208 mL; p < 0.001). CSFV was greater with composite atrophy (129.1 mL), than without (76.8 mL, p < 0.001). CSFV÷BV was greater with composite atrophy (12.3%), than without (6.7%, p < 0.001). Age was greater with composite atrophy (80.4 years), than without (76.3, p = 0.006). Age had an inverse correlation with BV (p < 0.001) and a direct correlation with CSFV (p = 0.0002) and CSFV÷BV (p < 0.001). ICH was greater with composite atrophy (49.4%), than without (15.6%; p < 0.001; odds ratio = 5.3). BV was lower with ICH (1,089 mL), than without (1,188 mL; p = 0.002). CSFV÷BV was greater with ICH (11.1 %), than without (8.7%, p = 0.02). ICH was independently associated with central atrophy (p = 0.001) and cortical atrophy (p = 0.003). CONCLUSIONS Simple 1-D measurements of age-related brain atrophy are associated with 3-D values. Clinical validity of these methods is also supported by their association with post-injury ICH. Intracranial 3-D software is not available on many CT scanners and can be cumbersome, when available. Simple 1-D measurements, using the study methodology, are a practical method to objectify the presence of age-related brain atrophy.
منابع مشابه
Three Dimensional Ultrasonography of the Eye and Measurement of Optical Nerve Sheet Diameter in Dog
Objective- To determine the possibility of three-dimensional ultrasonography (3DUS) and measurement of optical nerve sheet by this method. Design- Descriptive study. Animals- 10 mixed normal dogs (5males, 5 females), age 1-1.5 year, and weighting 15±5 kg Procedure- 3D ultrasounds of the eyes were evaluated and the normal optical nerves in 3DUS images were measured using Volouson 730 pro....
متن کاملPossibility and Reproducibility of Renal Assessing and Size Measurement by Three- Dimensional vs Two- Dimensional Ultrasounographv in Dogs
Objective- To determine the possibility and reproducibility of three-dimensional ultrasonography (3DUS)and comparison of the achieved measurements to normal two-dimensional ultrasonography (2DCS)Design- Descriptive studyAnimals- 10 young mixed normal dogs, age 1.5-2.5 year, weighing 9.7-12 kg Procedure- Renal width, length, and depth measured in coron al and transverse sections. The measurement...
متن کاملNumerical Scrutinization of Three Dimensional Casson-Carreau Nano Fluid Flow
This study presents the computational analysis of three dimensional Casson and Carreau nanofluid flow concerning the convective conditions. To do so, the flow equations are modified to nonlinear system of ODEs after using appropriate self-similarity functions. The solution for the modified system is evaluated by numerical techniques. The results show the impacts of involving variables on flow c...
متن کاملA two dimensional Simulation of crack propagation using Adaptive Finite Element Analysis
Finite element method (FEM) is one of the most famous methods which has many applications in varies studies such as the study of crack propagation in engineering structures. However, unless extremely fine meshes are employed, problem arises in accurately modelling the singular stress field in the singular element area around the crack tip. In the present study, the crack growth simulation has b...
متن کاملAirborne Seeker Application in Three Dimensional Formation Flight of UAVs
This paper deals with the leader-follower formation control problem while communication constraint in data transmitting is considered. From a practical point of view, we study the case in which unmanned vehicles are subject to the limited sensing, and communication is of a particular interest. A three-dimensional formation flight of multi-unmanned aerial vehicles with leader-follower configurat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMC medical imaging
دوره 16 شماره
صفحات -
تاریخ انتشار 2016