Hemodynamic parameters to guide fluid therapy

نویسندگان

  • Paul E Marik
  • Xavier Monnet
  • Jean-Louis Teboul
چکیده

The clinical determination of the intravascular volume can be extremely difficult in critically ill and injured patients as well as those undergoing major surgery. This is problematic because fluid loading is considered the first step in the resuscitation of hemodynamically unstable patients. Yet, multiple studies have demonstrated that only approximately 50% of hemodynamically unstable patients in the intensive care unit and operating room respond to a fluid challenge. Whereas under-resuscitation results in inadequate organ perfusion, accumulating data suggest that over-resuscitation increases the morbidity and mortality of critically ill patients. Cardiac filling pressures, including the central venous pressure and pulmonary artery occlusion pressure, have been traditionally used to guide fluid management. However, studies performed during the past 30 years have demonstrated that cardiac filling pressures are unable to predict fluid responsiveness. During the past decade, a number of dynamic tests of volume responsiveness have been reported. These tests dynamically monitor the change in stroke volume after a maneuver that increases or decreases venous return (preload) and challenges the patients' Frank-Starling curve. These dynamic tests use the change in stroke volume during mechanical ventilation or after a passive leg raising maneuver to assess fluid responsiveness. The stroke volume is measured continuously and in real-time by minimally invasive or noninvasive technologies, including Doppler methods, pulse contour analysis, and bioreactance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bench-to-bedside review: Functional hemodynamics during surgery - should it be used for all high-risk cases?

The administration of a fluid bolus is done frequently in the perioperative period to increase the cardiac output. Yet fluid loading fails to increase the cardiac output in more than 50% of critically ill and surgical patients. The assessment of fluid responsiveness (the slope of the left ventricular function curve) prior to fluid administration may thus not only help in detecting patients in n...

متن کامل

Assessment of hemodynamic efficacy and safety of 6% hydroxyethyl starch 130/0.4 vs. 0.9% NaCl fluid replacement in patients with severe sepsis: how to guide fluid therapy?

cacy of hydroxyethyl starch (HES) versus NaCl in patients with severe sepsis requires an algorithm to direct the timing and amount of fl uid resuscitation. Such an algorithm may include hemodynamic fl ow parameters. In a recent issue of Critical Care, Guidet and colleagues [1] reported that a smaller amount of 6% HES 130/0.4 versus 0.9% NaCl was required to achieve hemodynamic stability (HDS) d...

متن کامل

Restrictive versus Liberal Fluid Resuscitation in Children with Dengue Shock Syndrome: the differences in Clinical Outcomes and Hemodynamic Parameters

Background: Fluid resuscitation is the mainstay of treatment to counteract massive plasma leakage in dengue shock syndrome. We aimed to determine the differences in clinical outcomes and hemodynamic parameters of children with dengue shock syndrome post restrictive and liberal fluid resuscitation.  Materials and Methods: A retrospective observational study of pediatric patients who were betwee...

متن کامل

The Role of Transesophageal Echocardiography in the Intraoperative Period

The goal of hemodynamic monitoring and management during major surgery is to guarantee adequate organ perfusion, a major prerequisite for adequate tissue oxygenation and thus, end-organ function. Further, hemodynamic monitoring should serve to prevent, detect, and to effectively guide treatment of potentially life-threatening hemodynamic events, such as severe hypovolemia due to hemorrhage, or ...

متن کامل

Resistant hypertension: comparing hemodynamic management to specialist care.

Although resistant hypertension affects a minority of all hypertensives, this group continues to experience disproportionately high cardiovascular event rates despite newer antihypertensive agents. Hypertension represents an imbalance of hemodynamic forces within the circulation, usually characterized by elevated systemic vascular resistance. We studied the utility of serial hemodynamic paramet...

متن کامل

Goal-directed therapy in intraoperative fluid and hemodynamic management

Intraoperative fluid management is pivotal to the outcome and success of surgery, especially in high-risk procedures. Empirical formula and invasive static monitoring have been traditionally used to guide intraoperative fluid management and assess volume status. With the awareness of the potential complications of invasive procedures and the poor reliability of these methods as indicators of vo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2011