Absolute linearity measurements on a PbS detector in the infrared.

نویسنده

  • Evangelos Theocharous
چکیده

The nonlinearity characteristics of a commercially available thin-film photoconductive PbS detector were experimentally investigated in the infrared using the National Physical Laboratory detector linearity characterization facility. The deviation from linearity of this detector was shown to be significant even for relatively low values of radiant power incident on the active area of the detector. For example, the linearity factor was approximately 0.8 when 0.6 microW of radiant power at a wavelength of 2.2 microm was illuminating a spot of 1 mm in diameter on the active area of the PbS detector. These figures demonstrate the poor linearity characteristics of this detector and provide a warning to other users of PbS detection systems. The deviation from linearity was shown to be a function of the size of the spot being illuminated on the detector active area, as well as the wavelength of the incident radiation. The deviation from linearity was shown to be a function of irradiance illuminating the detector for irradiance values lower than 1 microW mm(-2).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conceptual Design and Simulation of Alpha-Beta Detector for Surface Contamination Measurements

The radioactive contamination measurement is essential in nuclear facilities. Monitoring of low level alpha and beta contamination is possible using light detectors high efficiency. Due to the fact that many detectors canchr('39')t simultaneously discriminate alpha, beta and gamma rays; among existing methods, phoswich detectors would be appropriate option to measure different radioactive conta...

متن کامل

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

Evaluate The Behavior of PIN infrared detector via COMSOL software

Infrared detectors can be used for a variety of applications such as: using in fiber-optic communications. Conventional technology for IR detectors is using p-i-n structure based on GaAs compound. This paper reports on the design and modeling of an IR detector using a p-i-n GaAs structure. Comsol software is used to simulate the model and the detector is discussed for terminal current, dopant p...

متن کامل

Study on Infrared Pbs Detector Prepared Using Copper Electrodes of Printed Circuit Board

Copper layers of Printed Circuit Board (PCB) have been used as electrodes for PbS infrared structure detector to introduce low cost and simple in preparation. PbS deposition as an active layer detector has been prepared for a few micrometers in thickness using an evaporation technique under vacuum pressure at 10 Torr. Photoconductivity phenomenon has been observed from the measurement when IR r...

متن کامل

Error Budget for a Calibration Demonstration System for the Reflected Solar Instrument for the Climate Absolute Radiance and Refractivity Observatory

A goal of the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is to observe highaccuracy, long-term climate change trends over decadal time scales. The key to such a goal is to improving the accuracy of SI traceable absolute calibration across infrared and reflected solar wavelengths allowing climate change to be separated from the limit of natural variability. The adva...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 46 25  شماره 

صفحات  -

تاریخ انتشار 2006