Comparison of fast protein liquid chromatography (FPLC) with HPLC, electrophoresis & microcolumn chromatography techniques for the diagnosis of beta-thalassaemia.

نویسندگان

  • S Tangvarasittichai
  • O Tangvarasittichai
  • N Jermnim
چکیده

BACKGROUND & OBJECTIVE beta-thalassaemia is a genetic disorder and an important health problem around the world. Quantitative haemoglobin A(2) (HbA(2)) levels are used for the diagnosis of beta-thalassaemia. The conventional methods are high performance liquid chromatography (HPLC), electrophoresis, and microcolumn chromatography techniques. We established a fast protein liquid chromatography (FPLC) method, to measure quantitatively of HbA(2) levels, and compared its efficacy with conventional methods. METHODS The FPLC method, using a DEAE Sepharose, Hi Trap anion-exchange column chromatography technique was set up for HbA(2) measurement. In this study, 220 blood samples were screened for haemoglobin type by FPLC technique and also using HPLC, microcolumn chromatography and electrophoresis. RESULTS The FPLC results were highly correlated (r = 0.985, P<0.001) with those of HPLC for quantification of HbA(2) as well as cellulose acetate electrophoresis (r = 0.977) and microcolumn chromatography (r = 0.980). The FPLC method showed 100 per cent sensitivity and specificity, positive and negative predictive value for beta-thalassaemia diagnosis. In addition, the FPLC method was simple, rapid, low cost and reproducible. The HbA(2)/E range of FPLC for beta-thalassaemia was 6-10 per cent, HbE trait was 10-40 per cent, beta-thalassaemia/HbE was 40-60 per cent and homozygous HbE was more than 60 per cent. INTERPRETATION & CONCLUSION Our findings suggested that FPLC method could be used as a cost-effective method for routine beta-thalassaemia diagnosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hb Q-India: an uncommon variant diagnosed in three Punjabi patients with diabetes is identified by a novel DNA analysis test.

AIMS An abnormality in the glycated haemoglobin peak (Hb A1c) on Diastat (Bio-Rad) cation exchange low pressure liquid chromatography (LPLC) was found in three Punjabi patients with diabetes. The aims of this study were to identify the variant by chromatography and electrophoresis and to determine whether a DNA analysis test could be designed for confirmation that could be generally applied for...

متن کامل

SEPARATION OF NONHISTONE HIGH MOBILITY GROUP (HMG) FROM HUMAN LYMPHOCYTES BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

The high mobility group (HMG) of nonhistone proteins have been investigated using two high performance liquid chromatographic techniques (HPLC). Reversed-phase HPLC under conditions of 50 mM triethylamine adjusted to pH 2.2 with phosphoric acid (solvent A) and 95% acetonitrile in water (solvent B) was used to separate proteins primarily on the basis of differences in the overall hydrophobi...

متن کامل

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

HbA2 levels in normal, beta-thalassaemia and haemoglobin E carriers by capillary electrophoresis.

OBJECTIVE The capillary electrophoresis (CE) is a new system that utilizes the principle of electrokinetic separation of molecules in eight electrolyte buffer-filled silica capillaries. In this study, we established the normal ranges of haemoglobin A2 (HbA2) and haemoglobin F (HbF) levels for normal individuals using this system and also the HbA2 level in beta thalassaemia and haemoglobin E (Hb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Indian journal of medical research

دوره 129 3  شماره 

صفحات  -

تاریخ انتشار 2009