Cross-sectional early mitral flow-velocity profiles from color Doppler in patients with mitral valve disease.
نویسندگان
چکیده
BACKGROUND Cross-sectional flow-velocity profiles from early mitral flow in 20 patients (10 with mitral regurgitation and 10 with mitral stenosis) were constructed from the velocity data from each point in sequentially delayed two-dimensional digital Doppler ultrasound maps. METHODS AND RESULTS The data suggested that the early mitral flow studied in an apical four-chamber view was variably skewed in both patient groups. The maximum flow velocity overestimated the cross-sectional mean velocity at the same time by a factor of 1.12-1.86. The maximum time-velocity integral was 1.13-1.77-fold greater than the cross-sectional mean time-velocity integral. In patients with mitral regurgitation, the cross-sectional flow-velocity profile appeared to be most skewed at the level of the mitral leaflet tips. The level of the mitral annulus appeared to give the most homogenous flow-velocity distribution in both patient groups. CONCLUSIONS When calculations of volume flow are based on pulsed Doppler ultrasound recordings with a single sample volume, the possibility of a skewed flow-velocity profile must be taken into account.
منابع مشابه
توانایی اکوکاردیوگرافی داپلر در تخمین فشار پرشدگی بطن چپ در تنگی دریچه میترال
Background: Estimation of Left Ventricular End Diastolic Pressure (LVEDP) among patients with Mitral Stenosis (MS) helps to diagnose diastolic dysfunction and to explain their symptoms. However, Conventional Doppler measurements have limitation in predicting of LVEDP. This study sought to establish whether the correlation between measurements derived from Tissue Doppler echocardiography and LVE...
متن کاملCalculation of aortic valve area by Doppler echocardiography: a direct application of the continuity equation.
The continuity equation suggests that a ratio of velocities at two different cardiac valves is inversely proportional to the ratio of cross-sectional areas of the valves. To determine whether a ratio of mitral/aortic valve orifice velocities is useful in determining aortic valve area in patients with aortic stenosis, 10 control subjects and 22 patients with predominant aortic stenosis were exam...
متن کاملTwo-dimensional mitral flow velocity profiles in pig models using epicardial Doppler echocardiography.
OBJECTIVES This study investigated the velocity distribution across the natural mitral valve. BACKGROUND Information about the blood velocity distribution across the mitral valve is of interest in basic fluid dynamic studies of the natural mitral valve and is needed for precise cardiac output estimates by Doppler echocardiography. METHODS The velocity distribution across the mitral valve wa...
متن کاملLeft ventricular filling in hypertrophic cardiomyopathy: a pulsed Doppler echocardiographic study.
Abnormal left ventricular diastolic properties have been described in patients with hypertrophic cardiomyopathy. To evaluate the diastolic filling characteristics of the left ventricle in patients with this disease, pulsed Doppler echocardiography was used to study mitral flow velocity in 17 patients with hypertrophic cardiomyopathy (11 with and 6 without systolic anterior motion of the mitral ...
متن کاملCross sectional early mitral flow velocity profiles from colour Doppler.
Instantaneous cross sectional flow velocity profiles from early mitral flow in 10 healthy men were constructed by time interpolation of the velocity data from each point in sequentially delayed two dimensional digital Doppler ultrasound maps. This interpolation allows correction of the artificially produced skewness of velocities across the flow sector caused by the time taken to scan the flow ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 86 3 شماره
صفحات -
تاریخ انتشار 1992