Synchrotron Radiation Total Reflection X-ray Fluorescence - Spectroscopy for Microcontamination Analysis on Silicon Wafer Surfaces

نویسنده

  • Norikatsu Takaura
چکیده

As dimensions in state-of-the-art CMOS devices shrink to less than 0.1 pm, even low levels of impurities on wafer surfaces can cause device degradation. Conventionally, metal contamination on wafer surfaces is measured using Total Reflection X-Ray Fluorescence Spectroscopy (TXRF). However, commercially available TXRF systems do not have the necessary sensitivity for measuring the lower levels of contamination required to develop new CMOS technologies. In an attempt to improve the sensitivity of TXRF, this research investigates Synchrotron Radiation TXRF (SR TXRF). The advantages of SR TXRF over conventional TXRF are higher incident photon flux, energy tunability, and linear polarization. We made use of these advantages to develop an optimized SR TXRF system at the Stanford Synchrotron Radiation Laboratory (SSRL). The results of measurements show that the Minimum Detection Limits (MDLs) of SR TXRF for 3-d transition metals are typically at a level-of 3x10* atoms/cm2, which is better than conventional TXRF by about a factor of 20. However, to use our SR TXRF system for practical applications, it was necessary to modify a commercially available Si (Li) detector which generates parasitic fluorescence signals. With the modified detector, we could achieve true MDLs of 3x10* atoms/cm2 for 3-d transition metals. In addition, the analysis of Al on Si wafers is described. Al analysis is difficult because strong Si signals overlap the Al signals. In this work, the Si signals are greatly

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Advances and Perspectives in Synchrotron Radiation TXRF

Total reflection x-ray fluorescence (TXRF) using Synchrotron Radiation is likely to be the most powerful non-destructive technique for the analysis of trace metal impurities on silicon wafer surfaces. Of fundamental importance in TXRF is the achievable sensitivity as characterized by the minimum detection limit. This work describes the progress we achieved recently at the Stanford Synchrotron R...

متن کامل

FEASIBILITY OF IN SITU TXRF, A. Singh, P. Goldenzweig, K. Baur, S. Brennan, P. Pianetta, pp. 554-560

Synchrotron radiation based total external reflection x-ray fluorescence spectroscopy (TXRF) is now being routinely used at the Stanford Synchrotron Radiation Laboratory (SSRL) to carry out industrially relevant measurements. For transition elements on Si wafer surfaces, detection limits of 8x10 atoms/cm that correspond to 1 impurity atom among 30 million substrate atoms have proven more than a...

متن کامل

Aluminum Impurities in Silicon: Investigation of X-ray Raman Scattering in Total Reflection X-ray Fluorescence Spectroscopy

Total Reflection X-ray Fluorescence (TXRF) using Synchrotron Radiation from the Stanford Synchrotron Radiation Laboratory (SSRL) has been used to study Al impurities on Si wafer surfaces. For primary excitation energies below the Si K absorption edge an inelastic resonance scattering due to resonant xray Raman scattering is observed. This scattering dominates the background behavior of the Al K...

متن کامل

Application of Synchrotron Radiation to TXRF analysis of metal contamination on silicon wafer surfaces

Synchrotron Radiation based Total Reflection X-ray Fluorescence (TXRF) has been shown to meet the critical needs of the semiconductor industry for the analysis of transition metal impurities on silicon wafer surfaces. The current best detection limit achieved at the Stanford Synchrotron Radiation Laboratory (SSRL) for Ni is 8 x 10 atoms/cm which is a factor of 50 better than what can be achieve...

متن کامل

Ultra-trace Speciation of Nitrogen Compounds in Aerosols Collected on Silicon Wafer Surfaces by Means of Txrf-nexafs

Total reflection X-ray fluorescence analysis (TXRF) using monochromatized undulator radiation in the PTB radiometry laboratory at the synchrotron radiation facility BESSY II has been employed to investigate the chemical state of nitrogen compounds in aerosols. The aerosol samples of different size fractions were deposited on silicon wafer surfaces in a May impactor. Using a thin window Si(Li) d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007