Clinical outcomes after heterogeneous overlap stenting with drug-eluting stents and bare-metal stents for de novo coronary artery narrowings.
نویسندگان
چکیده
When it is difficult to deliver multiple drug-eluting stents (DES) or when size constraints limit DES implantation, bare-metal stents (BMS) may be implanted contiguous to DES. However, the clinical outcomes after overlapping DES and BMS implantation are not known. From September 2004 to June 2006, 4,872 consecutive patients who underwent percutaneous coronary intervention consented to be enrolled in a prospective registry. Of these patients, 44 (0.9%) with de novo lesions were treated with DES and BMS overlap stenting. All patients were followed to 12 months for the assessment of clinical outcomes. The average implanted stent diameter was 2.68 +/- 0.30 mm for DES and 2.35 +/- 0.38 mm for BMS. Overlapping BMS were implanted distal to DES in all but 1 case. One patient (2.3%) experienced acute stent thrombosis and died 2 days after the procedure. No other patient died or had a myocardial infarction during 12 months. The target vessel revascularization rate at 12 months, however, was 31.8%, mainly driven by diffuse in-stent restenosis in the BMS segments. In conclusion, the incidence of DES and BMS overlap stenting is rare in daily practice, but this procedure is associated with a high rate of target vessel revascularization.
منابع مشابه
Outcomes following coronary stenting in the era of bare-metal vs the era of drug-eluting stents.
CONTEXT Although drug-eluting stents reduce restenosis rates relative to bare-metal stents, concerns have been raised that drug-eluting stents may also be associated with an increased risk of stent thrombosis. Our study focused on the effect of stent type on population-based interventional outcomes. OBJECTIVE To compare outcomes of Medicare beneficiaries who underwent nonemergent coronary ste...
متن کاملThe stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis
BACKGROUND Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. AIM We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. METHODS Sirolimus-eluting stents were implanted in 88 lesions a...
متن کاملCharacteristics and outcomes of patients with percutaneous coronary intervention for unprotected left main coronary artery disease: a Hong Kong experience.
OBJECTIVE To evaluate the intermediate-term outcomes of patients with unprotected left main coronary artery stenosis who were treated with percutaneous coronary intervention in Hong Kong. DESIGN Historical cohort. SETTING A regional hospital in Hong Kong. PATIENTS Patients with unprotected left main coronary artery disease undergoing stenting with bare-metal stents or drug-eluting stents ...
متن کاملImpact of sirolimus-eluting stents on outcome in diabetic patients: a SIRIUS (SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo coronary artery lesions) substudy.
BACKGROUND Randomized clinical trials have shown that a sirolimus-eluting stent significantly reduces restenosis after percutaneous coronary revascularization. Diabetic patients are known to have a higher risk of restenosis compared with nondiabetic patients. The purpose of this analysis was to determine the impact of sirolimus-eluting stents on outcomes of diabetic compared with nondiabetic pa...
متن کاملOutcomes with various drug eluting or bare metal stents in patients with diabetes mellitus: mixed treatment comparison analysis of 22 844 patient years of follow-up from randomised trials
OBJECTIVES To evaluate the efficacy and safety of currently used drug eluting stents compared with each other and compared with bare metal stents in patients with diabetes. DESIGN Mixed treatment comparison meta-analysis. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and CENTRAL were searched for randomised clinical trials, until April 2012, of four durable polymer drug eluting stents (s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of cardiology
دوره 101 1 شماره
صفحات -
تاریخ انتشار 2008