Analysis of the optical quality of intraocular lenses.
نویسندگان
چکیده
PURPOSE To evaluate the optical quality of different intraocular lenses (IOLs). METHODS An optical test bench and suitable software were used to assist in analysis of the optical Fourier transform (OFT) of a test image and to determine the quality of the lens in terms of spatial frequency response. The OFT was automatically converted, by means of an optical-electronic calibration procedure, into a modulation transfer function (MTF) for each lens. The passband value calculated by computer analysis of the MTF is an objective index of the lens quality. Three randomly acquired samples of 24 different models of foldable IOLs were compared. Statistical analysis was performed with two-way and one-way ANOVA for repeated measurements and with the Ryan-Einot-Gabriel-Welsch multiple F test. RESULTS The method was demonstrated to be precise and accurate. A large range of passband values was found. Statistically significant differences between the mean passband values for different lenses were found. The lowest passband value (125.60 line pairs [lp]/mm) was measured for the IOL (Lenstec LH3000; Lenstec, Inc., St. Petersburg, FL) and the highest (191.48 lp/mm) for the Acrysof SA30AL (Alcon, Fort Worth, TX). CONCLUSIONS Different IOLs can transmit different spectra of spatial frequencies. The best frequency response was provided by acrylic IOLs, particularly those with an asymmetrically biconvex profile. This could be due to a reduction of optical degradation provided by this type of profile. A lens with a higher frequency response should determine a better quality of vision once implanted and the frequency response should therefore be considered when choosing the intraocular lens model.
منابع مشابه
کاربرد لنزهای داخل چشمی در جراحی کاتاراکت و عوامل تأثیرگذار بر دید بیمار
Introduction: With the growing and rapid development of refractive surgery, researches focus increasingly on improvement of visual quality after cataract surgery. Intraocular lenses (IOLs) were a successful effort in the field of cataract surgery. Despite significant advances in cataract surgery, several complications related to surgical technique and IOL design after surgery can cause vision c...
متن کاملRetinal images in optomechanical eye model with monofocal intraocular lens
Intraocular lens (IOL) is an artificial lens implanted into the eye. It usually replaces the existing crystalline lens, which is clouded over due to a cataract. In order to evaluate the optical performance of different IOLs an optomechanical model of human eye was developed. This model closely reproduces anatomical and optical properties of the average human eye. This makes it possible to measu...
متن کاملThrough focus image quality of eyes implanted with monofocal and multifocal intraocular lenses
Intraocular lenses (lOLs) are commonly implanted in cataract surgery. Initially lOLs were mainly monofocal, but at present there are many multifocal lOLs available, which are being implanted. Multifocal lOLs have the potential advantage of reducing the dependence on spectacle correction for near vision after cataract surgery. Because the multifocal lOLs superimpose the near and far images on th...
متن کاملAnalysis of New Laser Warning Technologies to Propose a New Optical Subsystem
In this paper, after a brief overview on laser warning system (LWS), a new structure for an optical array that is used in its optical subsystem is introduced. According to the laser threats’ wavelengths (0.5 – 1.6 µm) and our desirable field of view (FOV), we used 6 lenses for gathering the incident radiation and then optimized the optical array. Lenses’ radius, their se...
متن کاملHalo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses.
PURPOSE To compare, as a function of pupil size, the through-focus performance and halo features of four diffractive intraocular lenses (IOLs). METHODS Three diffractive bifocal IOLs (ReSTOR +2.5 D SV25T0, Tecnis +2.75 D ZKB00, and AT LISA +3.75 D 809M) and a diffractive trifocal IOL (AT LISA tri +3.33 D, +1.66 D 839MP) were tested in vitro in a modified International Organization for Standar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 45 8 شماره
صفحات -
تاریخ انتشار 2004