Towards Practical Breast Diffusion Tensor Imaging at 3.0T in the Clinical Setting

نویسندگان

  • T. Yankeelov
  • J. C. Gatenby
  • E. B. Welch
  • B. Chakravarthy
  • D. Freehardt
  • I. Mayer
  • M. Kelley
  • I. Meszoely
چکیده

INTRODUCTION Diffusion weighted MRI (DW-MRI) is a promising surrogate biomarker for the characterization of human breast cancer (1-4). Unfortunately, the quality of DW-MRI data is frequently compromised, especially in the breast, by the presence of main magnetic field (B0) inhomogeneities which can lead to geometric distortion in the echo planar imaging (EPI) techniques typically used to acquire such data. As the demand for higher temporal and spatial resolution increases in breast imaging, there is some motivation to move to higher (≥ 3.0T) fields (5) and this will increase the difficulty of acquiring quality DW-MRI data of the breast. Thus, we have begun investigating the ability of B0 field map corrections to reduce geometric distortion in diffusion tensor imaging (DTI) data obtained at 3.0T in a clinically relevant time period. METHODS Acquisition Data from six patients has thus far been analyzed. Patients were ≥ 18 years of age with biopsy-proven infiltrating breast cancer, stages IIA to IIIB and ECOG performance status 0 to 1. MRI was performed on a Philips 3.0 T Achieva scanner (Philips Healthcare, Best, The Netherlands) prior to all therapy. A double-breast 4-channel receive coil was used for all imaging (In vivo Inc., Gainesville, FL). The DTI acquisition employed a fat-suppressed, single shot EPI sequence with TR\TE\α\NSA = 2500ms\45ms\90\10, b-values of 0 and 500 s/mm in six directions (applied sequentially), and an imaging matrix of 80 (zero-filled to 128) acquired over sagitally over a (25.6 cm) FOV. Just prior to DTI, a double gradient echo was acquired to produce a B0 field map with TR\TE1\TE2\α\NSA= 645ms\2.3ms\4.6ms\40\1. The MR session, including a dynamic contrast enhanced (DCE) study, is approximately 25 minutes. Analysis Matlab (Mathworks, Natick, MA) was used to implement the method of Jezzard and Balaban (6) in which field maps were constructed and used to correct for pixel shifts in the phase encode direction due to B0 inhomogeneities present in the EPI data. DW images through the central slice of the tumors both with and without B0 correction were compared to anatomical and DCE images. RESULTS Figure 1a depicts a sagittal, pre-contrast T1-weighted image, while panel b is a postcontrast subtraction image showing the localization of the lesion. The original b=500 s/mm image is shown in panel c and displays significant geometric distortions; panel d is the corresponding ADC map in which the tumor is visible (white arrow) as an area of decreased intensity most likely due to increased cellularity resulting in decreased water diffusion. Panels e and f present the corresponding post-correction data of panels c and d, respectively. The post-correction data display significantly less distortion as evidenced by the better matching of the contour of the breast seen in panel a. The lesion is also more easily seen on the corrected ADC map (panel f). (Due to space limitations, we have only considered the ADC maps and not the fractional anisotropy maps.) CONCLUSION and DISCUSSION We have presented preliminary evidence suggesting that correcting DTI data via a B0 map can lead to superior quality DTI data in terms of less distortion and better tumor localization when compared to anatomical and DCE data. Reducing geometric distortion in DTI data facilitates the comparison of derived DTI parameters with those obtained from, for example, DCE pharmacokinetic parameters. Furthermore, just as Jezzard and Balaban noted (6), collecting data for quality field maps requires only a minimum amount of additional scan time and may be easily incorporated into existing protocols. Thus, we conclude that this straightforward method be further explored to potentially improve the quality of breast DTI data obtained at high fields in clinically relevant scan times.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Benefits and implementations of Diffusion tensor imaging and Neural Fiber Tractography in Brain Surgery

Background and Aim: The methods for detecting brain activation with fMRI, MRI provides a way to measure the anatomical connections which enable lightning-fast communication among neurons that specialize in different kinds of brain functions. Diffusion tensor imaging is able to measure the direction of bundles of the axonal fibers which are all aligned. Besides mapping white matter fiber tracts,...

متن کامل

Fiber Tractography and Diffusion Tensor Imaging in Children with Agenesis and Dysgenesis of Corpus Callosum: A Clinico-Radiological Correlation

Background Corpus callosum is the largest commissure in human brain. It consists of tightly packed white matter tracts connecting the two cerebral hemispheres.  In this study we aimed to evaluate role of fiber tractography (FT), and diffusion tensor imaging (DTI) in ped...

متن کامل

Evaluation of Soft Tissue Sarcoma Tumors Electrical Conductivity Anisotropy Using Diffusion Tensor Imaging for Numerical Modeling on Electroporation

Introduction: There is many ways to assessing the electrical conductivity anisotropyof a tumor. Applying the values of tissue electrical conductivity anisotropyis crucial in numerical modeling of the electric and thermal field distribution in electroporationtreatments. This study aims to calculate the tissues electrical conductivityanisotropy in patients with sarcoma tumors using diffusion tens...

متن کامل

Diffusion Tensor Imaging for Glioma Grading: Analysis of Fiber Density Index

Introduction: The most common primary tumors of brain are gliomas and tumor grading is essential for designing proper treatment strategies. The gold standard choice to determine grade of glial tumor is biopsy which is an invasive method. The purpose of this study was to investigatethe role of fiber density index (FDi) by means of diffusion tensor imaging (DTI) (as a noninvasive method) in glial...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008